Comparison of Two Toric IOLs with Different Haptic Design: Optical Quality after 1 Year

نویسندگان

  • Kata Miháltz
  • Michael Lasta
  • Michael Burgmüller
  • Pia Veronika Vécsei-Marlovits
  • Birgit Weingessel
چکیده

Background The purpose of this prospective, randomised study was to interocularly compare the visual performance after implantation of two different toric IOLs with different haptic design. Methods 59 subjects with corneal astigmatism greater than 1.25 diopter (D) were implanted with an AT TORBI 709M IOL (Carl Zeiss Meditec AG) in one eye and with a Tecnis toric aspheric IOL (Abbot Medical Optics) in the other eye. Observation procedure was performed 12 months postoperatively. Main outcome measures included uncorrected distance visual acuity (UDVA), manifest refraction, IOL rotation, and IOL position. Results Mean UCDVA was 0.04 ± 0.14 logMAR for AT TORBI eyes and 0.06 ± 0.15 logMAR for Tecnis eyes (p = 0.3). The postoperative spherical equivalent values were significantly lower in the AT TORBI group. Mean toric IOL axis rotation was 3.0 ± 2.26 degrees for AT TORBI eyes and 3.27 ± 2.37 for Tecnis eyes (p = 0.5). The mean vertical IOL tilt and vertical decentration values measured with the Visante OCT were significantly larger in the AT TORBI group (p < 0.05). Conclusions Both the Tecnis and the AT TORBI toric IOLs successfully reduced ocular astigmatism. Emmetropia could be better achieved with the AT TORBI IOL, whereas the Tecnis showed better positional stability. This trial is registered with ICMJE NCT03371576.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design

PURPOSE To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic ...

متن کامل

Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases.

PURPOSE To determine whether rotational stability is improved with the longer Staar toric intraocular lens (IOL). SETTING A private practice, Los Altos, California, USA. METHODS Staar Surgical manufactures toric plate-haptic IOLs under +24.0 diopters (D) in 2 lengths. Fifty consecutive eyes requiring toric IOL spherical powers less than +24.0 D received the longer toric IOL (TL; 11.2 mm) us...

متن کامل

Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.

PURPOSE To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs. SETTING Private practice, Los Altos, California, USA. METHODS One hundred consecutive eyes with an AcrySof SN60T(3, 4, or 5) toric IOL were compared with a consecutive series of 90 AA4203 (TL or TF) toric IOLs. The same su...

متن کامل

نتایج درازمدت نصب اسکلرال لنزهای داخل چشمی جابجا شده به روش خارج کردن هاپتیک از برش کوچک قرنیه

    Background & Aim: Several methods have been reported for refixation of dislocated intraocular lenses (IOLs). However, these methods are associated with some disadvantages including vitreous prolaps, vitreous traction, ocular collapse, intraocular hemorrhage, high astigmatism, and the need for complex intraocular maneuvers. The aim of this study was to evaluate the results of transscleral fi...

متن کامل

Enhancement of Refractive Results after Intraocular Lens Implantation

Summary: An overview on polypseudophakia (‘piggyback’ intraocular lens [IOLs]) is given. Requirements on a sulcus-supported supplementary IOL are defined. Two-year results of a new IOL (Sulcoflex®) are presented and indications for this IOL are defined. Methods: The IOL is especially designed for implantation into the ciliary sulcus in pseudophakic eyes (piggyback). It is a single-piece implant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2018  شماره 

صفحات  -

تاریخ انتشار 2018