Evaluation of Two Facebow/Semi-adjustable Articulator Systems for Orienting Maxillary Cast on Articulators: A Pilot Study.

نویسندگان

  • C V Anusha
  • Amith A Singh
  • George Sam
  • Babita Sangwan
  • M Shilpa
  • Akshata G Kamath
چکیده

AIM The present study was aimed to assess the transferability of occlusal plane (OP) orientation from the patient to the articulators with the help of two different facebow systems and evaluated with a gold standard. MATERIALS AND METHODS Twenty dentate patients were selected for the study. Two semi-adjustable arcon articulators that are Hanau Wide(®) Vue using SpringBow and Whip Mix(®) using quick-mount facebow were used in the study. Mean angle between OP to horizontal reference plane obtained from Hanau Wide Vue articulator system (SpringBow using Orbitale as anterior reference point) and Whip Mix articulator system (quickmount facebow using nasion as anterior reference point) was tabulated. These values obtained were further compared with each other and evaluated against cephalometric evidence, which was considered as the gold standard for the study. Descriptive statistics, analysis of variance, Scheffe post hoc analysis for group comparison, and level of significance (P) was calculated using Statistical Package for the Social Sciences version 16 (IBM, New York, USA) software program. RESULTS Intragroup comparison of mean angle OP values showed highly significant difference (p = 0.000). Comparison between Hanau Wide Vue articulator system and Whip Mix articulator system showed statistically highly significant with a mean difference of 10.51° with Hanau system values being lower than Whip Mix system. Difference between Hanau system and cephalometric values were statistically significant with a mean difference of 2.835° and Hanau system consistently recording lower values than cephalometric values. Difference between Whip Mix system and cephalometric values was also statistically significant with a mean difference of 7.680° with group 2 values were on average 7.680° higher than group 3. CONCLUSION Within the limitations of this study, the Hanau system and Whip Mix system showed significant difference in reproduction of angle between OP and horizontal reference plane. Hanau articulator system showed closer values to that of cephalometric values in comparison with Whip Mix articulator system. CLINICAL SIGNIFICANCE Orientation of the maxillary cast in an articulator is a crucial part of several techniques used in dentistry. Orientation of maxillary cast in the articulator acts as a baseline from which further steps for occlusal rehabilitation of the patients are carried out. Recording and transferring of the occlusal cant to articulators require facebow.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of accuracy of transfer of the maxillary occlusal cant of two articulators using two facebow/semi-adjustable articulator systems: An in vivo study

AIM The aim of this study was to compare the accuracy of the angle made by Frankfort horizontal plane-occlusal plane on maxillary casts, mounted using the respective facebows on Artex Amann Girrbach and Hanau Wide-vue semi-adjustable articulators with cephalometrically derived Frankfort horizontal plane-occlusal plane angle as a control. SUBJECTS AND METHODS Maxillary casts of 30 subjects wer...

متن کامل

A Comparison of Two Methods to Articulate a Maxillary Cast with Lateral Cephalometry

A COMPARISON OF TWO METHODS TO ARTICULATE A MAXILLARY CAST WITH LATERAL CEPHALOMETRY Laura H. Lux D.D.S Marquette University, 2014 The Kois Dento-Facial Analyzer, an arbitrary articulation system, is used by clinicians to articulate and evaluate clinical cases. There is, however, limited information for understanding how the Kois Dento-Facial Analyzer should be utilized. Dr. Kois and Dr. Lee or...

متن کامل

A Comparative Study of Facebow Transfer on Hanau and Whip-mix Articulators

Received 13/07/92; revised 01/12/92; accepted 20/04/93 * Assistant Professor, Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University ** Lecturer, Department of Restorative Dental Sciences, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia. Address reprint requests to: Dr. M. A. Abdullah * Teledyne Hanau, P.O. Box 203,80 Sonwil D...

متن کامل

Relationship between the Preferred Chewing Side and the Angulation of Anterior Tooth Guidance

OBJECTIVES The aim of this study was to evaluate a possible relationship between preferred chewing side (PCS) and the anterior guidance angle. SUBJECTS AND METHODS Forty dental nurses and technicians, aged 24-46 years, were each given a piece of chewing gum, which they chewed for about 3 min. At 7 regular intervals (every 15 s), they were interrupted by the principal investigator (P.L.) in or...

متن کامل

Determination of Incisal Point as Anterior Guide to Transfer Maxillary Casts to Articulator: A Pilot Study

Objectives Despite the importance to use face-bow record for transferring maxillary cast to articulator some dentists use average points to avoid the time taken and ease of use. The location of incisal point could help to set the maxillary cast or denture in an appropriate position in mounting stage. This study was designed to determine the incisal point location in ante...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2016