The European System for Cardiac Operative Risk Evaluation (EuroSCORE) is not appropriate for withholding surgery in high-risk patients with aortic stenosis: a retrospective cohort study

نویسندگان

  • Dimitri Kalavrouziotis
  • Debbie Li
  • Karen J Buth
  • Jean-Francois Légaré
چکیده

BACKGROUND The European System for Cardiac Operative Risk Evaluation (EuroSCORE) is a widely used risk assessment tool in patients with severe aortic stenosis to determine operability and to select patients for alternative therapies such as transcatheter aortic valve implantation. The objective of this study was to determine the accuracy of the EuroSCORE in predicting mortality following aortic valve replacement (AVR). METHODS The logistic EuroSCORE was determined for all consecutive patients that underwent conventional AVR between 1995 and 2005 at our institution. Provincial Vital Statistics were used to determine all-cause mortality. The accuracy of the prognostic risk prediction provided by logistic EuroSCORE was assessed by comparing observed and expected operative mortality. RESULTS During the study period, a total of 1,421 patients underwent AVR including 237 patients (16.7%) that had a logistic EuroSCORE > 20. Among these patients, the mean predicted operative mortality was 38.7% (SD = 18.1). The actual mortality of these patients was significantly lower than that predicted by EuroSCORE (11.4% vs. 38.7%, observed/expected ratio 0.29, 95% CI 0.15-0.52, P < 0.05). The EuroSCORE overestimated mortality within all strata of predicted risk. Although medium-term mortality is significantly higher among patients with EuroSCORE > 20 (log rank P = 0.0001), approximately 60% are alive at five years. CONCLUSION Actual operative mortality in patients undergoing AVR is significantly lower than that predicted by the logistic EuroSCORE. Additionally, medium-term survival following AVR is acceptable in high-risk patients with EuroSCORE > 20. More accurate risk prediction models are needed for risk-stratifying patients with severe aortic stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The prospective validation of EuroSCORE II risk scoring system for patients underwent cardiac surgery: brief report

Background: Various prediction models have been developed aiming to estimate risk-adjusted mortality, morbidity and length of intensive care unit stay following cardiac surgeries. The European system for cardiac operative risk evaluation II (EuroSCORE II) is a prediction model which maps 18 predictors to a 30-day post-operative risk of death. The objective of this study was to evaluate the perf...

متن کامل

Conventional aortic valve replacement in patients with concomitant coronary artery disease and previous coronary artery bypass grafting in the era of interventional approaches.

OBJECTIVE In patients with symptomatic aortic valve stenosis and a high estimated operative risk due to previous coronary artery bypass grafting (CABG) procedures, interventional aortic valve implantation techniques may ultimately prove superior. However, recent studies have revealed increased mortality and impaired survival in patients with concomitant coronary artery disease (CAD). METHODS ...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

The logistic EuroSCORE predicts the hospital mortality of the thoracic aortic surgery in consecutive 327 Japanese patients better than the additive EuroSCORE.

OBJECTIVE Risk stratification in thoracic aortic surgery is a topic of major interest. Recent studies have shown the European System for Cardiac Operative Risk Evaluation (EuroSCORE) to be an extremely useful and reliable risk stratification score and also a good indicator of quality of care in cardiac surgery. The purpose of this study was to evaluate the significance of the additive and logis...

متن کامل

The Chinese coronary artery bypass grafting registry study: how well does the EuroSCORE predict operative risk for Chinese population?

OBJECTIVE The European System for Cardiac Operative Risk Evaluation (EuroSCORE) model is a widely used risk prediction algorithm for cardiac surgery in China due to lack of a local model, although its validation has never been tested. The aim of this study was to assess the performance of the logistic EuroSCORE when applied in the Chinese Coronary Artery Bypass Grafting Registry database, which...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Cardiothoracic Surgery

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2009