The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases

نویسندگان

  • Mohammad Davood Sharifi
  • Hamid Zamani Moghaddam
  • Hosein Zakeri
  • Mohsen Ebrahimi
  • Hesamoddin Saeedian
  • Amir Masoud Hashemian
چکیده

INTRODUCTION Scaphoid fracture is the most common fracture among the bones of the wrist. Plain radiography has a sensitivity of 59 to 79 percent for the diagnosis of scaphoid fracture after injury. Casting is done to avoid complications in patients with suspected fractures with normal radiography. Magnetic resonance imaging (MRI) has a sensitivity of 100% and a specificity of 99%. To avoid unnecessary casting and high costs, we decided to offer a way more efficient than radiography and less costly than MRI. MATERIAL AND METHODS In the present study, 175 patients with suspected scaphoid fracture along with snuff box tenderness and normal radiography were enrolled in the study. On arrival, patients' pain score were determined using visual analog scale method with anatomical snuffbox tenderness and then MRI was performed on the patients' wrist and the results were recorded for patient in the check list. The data was then aggregated and analyzed. RESULTS The result of MRI for fracture was negative for 90.9% and positive for 9.1%. The mean pain score was 7.3 in negative MRI group and 8.75 in positive MRI group, considering a significant difference. ROC curve graph showed that the sensitivity and specificity will be 87% and 57%, respectively for scores 7.5 and higher and 75% and 72%, respectively for scores 8.5 and higher. CONCLUSION It seems that although this method, beside other criteria in the diagnosis of fractures, can be useful in future studies, it would not be helpful in fracture detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter-observer agreement between 2-dimensional CT versus 3-dimensional I-Space model in the Diagnosis of Occult Scaphoid Fractures

  Background: The I-Space is a radiological imaging system in which Computed Tomography (CT)-scans can be evaluated as a three dimensional hologram. The aim of this study is to analyze the value of virtual reality (I-Space) in diagnosing acute occult scaphoid fractures.   Methods: A convenient cohort of 24 patients with a CT-scan from prior studies, without a scaphoid fracture on radiograph, ye...

متن کامل

Comparison of CT and MRI for diagnosis of suspected scaphoid fractures.

BACKGROUND There is no consensus on the optimum imaging method to use to confirm the diagnosis of true scaphoid fractures among patients with suspected scaphoid fractures. This study tested the null hypothesis that computed tomography (CT) and magnetic resonance imaging (MRI) have the same diagnostic performance characteristics for the diagnosis of scaphoid fractures. METHODS Thirty-four cons...

متن کامل

O-19: A Comparison of Pelvic Magnetic Resonance Imaging, Trans-Vaginal and Trans-Rectal Sonography with Laparoscopic Findings in The Diagnosis of Deep Infiltrating Endometriosis

Background The performance of TVS, TRS and MRI for the diagnosis of DIE have been separately reported in earlier studies. However, the three methods have not been concurrently compared in terms of their overall performance and classified results as per different anatomical locations of DIE lesions in a large study population. This study was an attempt to compare pelvic magnetic resonance imagin...

متن کامل

Evaluation and diagnosis of wrist pain: a case-based approach.

Patients with wrist pain commonly present with an acute injury or spontaneous onset of pain without a definite traumatic event. A fall onto an outstretched hand can lead to a scaphoid fracture, which is the most commonly fractured carpal bone. Conventional radiography alone can miss up to 30 percent of scaphoid fractures. Specialized views (e.g., posteroanterior in ulnar deviation, pronated obl...

متن کامل

Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging

Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 69  شماره 

صفحات  -

تاریخ انتشار 2015