Orientation and size-dependent mechanical modulation within individual secondary osteons in cortical bone tissue.

نویسندگان

  • Davide Carnelli
  • Pasquale Vena
  • Ming Dao
  • Christine Ortiz
  • Roberto Contro
چکیده

Anisotropy is one of the most peculiar aspects of cortical bone mechanics; however, its anisotropic mechanical behaviour should be treated only with strict relationship to the length scale of investigation. In this study, we focus on quantifying the orientation and size dependence of the spatial mechanical modulation in individual secondary osteons of bovine cortical bone using nanoindentation. Tests were performed on the same osteonal structure in the axial (along the long bone axis) and transverse (normal to the long bone axis) directions along arrays going radially out from the Haversian canal at four different maximum depths on three secondary osteons. Results clearly show a periodic pattern of stiffness with spatial distance across the osteon. The effect of length scale on lamellar bone anisotropy and the critical length at which homogenization of the mechanical properties occurs were determined. Further, a laminate-composite-based analytical model was applied to the stiffness trends obtained at the highest spatial resolution to evaluate the elastic constants for a sub-layer of mineralized collagen fibrils within an osteonal lamella on the basis of the spatial arrangement of the fibrils. The hierarchical arrangement of lamellar bone is found to be a major determinant for modulation of mechanical properties and anisotropic mechanical behaviour of the tissue.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relation of collagen fiber orientation to some mechanical properties of human cortical bone.

The percentage of dark. light, and intermediate osteons and their fragments. a\ seen in polarized light, was determined for 53 cross-sections of emhalmed, adult human bone. Dark osteons have collagen fibers predominantly parallel with the long axis of the osteon while in light osteons the fibers are at a sharp angle to the long axis of the osteon. Intermediate osteons

متن کامل

Secondary osteons scale allometrically in mammalian humerus and femur

Intra-cortical bone remodelling is a cell-driven process that replaces existing bone tissue with new bone tissue in the bone cortex, leaving behind histological features called secondary osteons. While the scaling of bone dimensions on a macroscopic scale is well known, less is known about how the spatial dimensions of secondary osteons vary in relation to the adult body size of the species. We...

متن کامل

Relations of the compressive properties of human cortical bone to histological structure and calcification.

Compressive properties were determined for 65 standardized specimens of wet. unembalmed cortical bone from tibias of six men. Osteons were classified as dark. light or intermediate from their appearance m polarized light and as slightly, intermediately or markedly radiolucent from their apprarancc in microradiographs. Compressive strength had significant positive correlations with the percent 0...

متن کامل

Changes in compact bone microstructure of rats subchronically exposed to cadmium

BACKGROUND Chronic exposure to cadmium (Cd), even at low concentrations, has an adverse impact on the skeletal system. Histologically, primary and secondary osteons as basic structural elements of compact bone can also be affected by several toxicants leading to changes in bone vascularization and mechanical properties of the bone. The current study was designed to investigate the effect of sub...

متن کامل

Osteon interfacial strength and histomorphometry of equine cortical bone.

The interfacial strength of secondary osteons from the diaphysis of the Thoroughbred equine third metacarpal was evaluated using the fiber pushout test. The pushout was performed on 300-500 microm sections of 4x4x15 mm bone blocks machined from four anatomic regions of the cortex. Pushout strength was evaluated from proximal to distal location within the diaphysis on four osteon types classifie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the Royal Society, Interface

دوره 10 81  شماره 

صفحات  -

تاریخ انتشار 2013