MRI Signal Intensity Analysis of Novel Protein-based MRI Contrast Agents

نویسندگان

  • Yan Qian
  • YAN QIAN
  • Gengsheng Qin
  • Jenny J. Yang
  • Xin Qi
  • Shenghui Xue
چکیده

Contrast agents are of great importance in clinical applications of Magnetic Resonance Imaging (MRI) to improve the contrast of internal body structures and to obtain tissue-specific image. However, current approved contrast agents still have limitations including low relaxivity, low specificity and uncontrolled blood circulation time, which motivated researchers to develop novel contrast agents with higher relaxivity, improved targeting abilities and optimal retention time. This thesis uses animal experimental data from Dr. Jenny J. Yang’s lab at the Department of Chemistry in Georgia State University to study effects of a class of newly designed proteinbased MRI contrast agents (ProCAs). Models for the longitudinal data on MRI intensity are constructed to evaluate the efficiency of different MRI contrast agents. Statistically significant results suggest that ProCA1B14 has the great potential to be a tumor specific contrast agent and ProCA32 could be a promising MRI contrast agent for the liver imaging in clinical applications. INDEX WORDS: Contrast agent, Linear mixed effects model, Longitudinal study, MRI, Protein-based MRI contrast agents (ProCA), ProCA1, ProCA1B14, ProCA32 MRI SIGNAL INTENSITY ANALYSIS OF NOVEL PROTEIN-BASED MRI CONTRAST AGENTS

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potential positive MRI contrast agent based on PVP-grafted superparamagnetic iron oxide nanoparticles with various repetition times

Objective(s): The present study aimed to evaluate the capability of synthesized and modified superparamagnetic iron oxide nanoparticles (SPIONs) as the positive contrast agent in magnetic resonance imaging (MRI) by investigating the effect of repetition time (TR) on the MRI signal intensity. Materials and Methods: SPIONs were synthesized using the co-precipitation method, and their surfac...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

Glucosamine Conjugated Gadolinium (III) Oxide Nanoparticles as a Novel Targeted Contrast Agent for Cancer Diagnosis in MRI

Background: Glucose transporter (Glut), a cellular transmembrane receptor, has a key role in the metabolism of cell glucose and is also associated with various human carcinomas.Objective: In this study, we evaluated a magnetic resonance (MR) imaging contrast agent for tumor detection based on paramagnetic gadolinium oxide (Gd2O3) coated polycyclodextrin (PCD) and mod...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

A novel MRI contrast agent synthesized by ion exchange method

Objective: In this study, the zeolite-coated iron oxide nanoparticles were evaluated as MRI contrast agent and effect of the nanocomposite synthesis method on MRI contrast was tested. Materials and Methods: Ion exchange method was used for synthesis of iron oxide-zeolite and the as prepared nanocomposite was characterized by XRD, FESEM and TEM. The nanocomposite toxicity in the cell culture, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015