Evaluation of prospective motion correction of high-resolution 3D-T2-FLAIR acquisitions in epilepsy patients.

نویسندگان

  • Sjoerd B Vos
  • Caroline Micallef
  • Frederik Barkhof
  • Andrea Hill
  • Gavin P Winston
  • Sebastien Ourselin
  • John S Duncan
چکیده

T2-FLAIR is the single most sensitive MRI contrast to detect lesions underlying focal epilepsies but 3D sequences used to obtain isotropic high-resolution images are susceptible to motion artefacts. Prospective motion correction (PMC) - demonstrated to improve 3D-T1 image quality in a pediatric population - was applied to high-resolution 3D-T2-FLAIR scans in adult epilepsy patients to evaluate its clinical benefit. Coronal 3D-T2-FLAIR scans were acquired with a 1mm isotropic resolution on a 3T MRI scanner. Two expert neuroradiologists reviewed 40 scans without PMC and 40 with navigator-based PMC. Visual assessment addressed six criteria of image quality (resolution, SNR, WM-GM contrast, intensity homogeneity, lesion conspicuity, diagnostic confidence) on a seven-point Likert scale (from non-diagnostic to outstanding). SNR was also objectively quantified within the white matter. PMC scans had near-identical scores on the criteria of image quality to non-PMC scans, with the notable exception that intensity homogeneity was generally worse. Using PMC, the percentage of scans with bad image quality was substantially lower than without PMC (3.25% vs. 12.5%) on the other five criteria. Quantitative SNR estimates revealed that PMC and non-PMC had no significant difference in SNR (P=0.07). Application of prospective motion correction to 3D-T2-FLAIR sequences decreased the percentage of low-quality scans, reducing the number of scans that need to be repeated to obtain clinically useful data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quiet PROPELLER MRI techniques match the quality of conventional PROPELLER brain imaging techniques.

BACKGROUND AND PURPOSE Switching of magnetic field gradients is the primary source of acoustic noise in MR imaging. Sound pressure levels can run as high as 120 dB, capable of producing physical discomfort and at least temporary hearing loss, mandating hearing protection. New technology has made quieter techniques feasible, which range from as low as 80 dB to nearly silent. The purpose of this ...

متن کامل

Comparison of the added value of contrast-enhanced 3D fluid-attenuated inversion recovery and magnetization-prepared rapid acquisition of gradient echo sequences in relation to conventional postcontrast T1-weighted images for the evaluation of leptomeningeal diseases at 3T.

BACKGROUND AND PURPOSE The usefulness of contrast-enhanced 3D T2-FLAIR MR imaging for the evaluation of leptomeningeal diseases has not been systematically investigated. The purpose of this study was to assess the value added by contrast-enhanced 3D T2-FLAIR and MPRAGE sequences to conventional postcontrast T1-weighted images in the evaluation of leptomeningeal diseases. We also undertook in vi...

متن کامل

Prospective Motion Correction with Stereoscopic Optical Tracking at 7T

INTRODUCTION Artifacts caused by motion during the image acquisition are a well known problem at 1.5T and 3T. In high field systems such as 7T the available signal to noise ratio leads to potentially higher resolution than in systems with lower field. Unfortunately higher resolution requires longer acquisition times without patient motion. Therefore an increased need for motion correction exist...

متن کامل

Improved Diagnostic Utility of T2-weighted 3D-TSE Liver Imaging by Suppression of Vascular Signals using a Motion- Sensitive Preparation

Introduction: Single-slab, three-dimensional turbo/fast spin-echo (3D-TSE) pulse sequences with variable-flip-angle refocusing RF pulses [1,2] (e.g., SPACE [Siemens] or 3D FSE CUBE [GE]), when combined with navigator-based respiratory triggering, provide a sufficiently high sampling efficiency to permit high-resolution, T2-weighted 3D imaging of the liver in a clinically-reasonable acquisition ...

متن کامل

Automated White Matter Hyperintensity Detection in Multiple Sclerosis Using 3D T2 FLAIR

White matter hyperintensities (WMH) seen on T2WI are a hallmark of multiple sclerosis (MS) as it indicates inflammation associated with the disease. Automatic detection of the WMH can be valuable in diagnosing and monitoring of treatment effectiveness. T2 fluid attenuated inversion recovery (FLAIR) MR images provided good contrast between the lesions and other tissue; however the signal intensi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neuroradiology. Journal de neuroradiologie

دوره   شماره 

صفحات  -

تاریخ انتشار 2018