A specific in vitro bioassay for measuring erythropoietin levels in human serum and plasma.
نویسندگان
چکیده
The accurate measurement of biologically active erythropoietin (Ep) in human serum and plasma using present in vivo and in vitro bioassays is difficult because of the presence of both inhibitors and non-Ep stimulators of erythropoiesis. We have developed a simple procedure to quantitatively purify Ep from serum and plasma for subsequent testing in the phenylhydrazine-treated mouse spleen cell assay. The method involves absorption of Ep to an immobilized high-affinity anti-Ep monoclonal antibody and acid elution of the antibody-bound material. After neutralization, the eluted EP is then tested directly in the in vitro bioassay without interference by other serum proteins. By using magnetic beads as a solid support for the antibody, washing and elution steps can be performed rapidly and efficiently. Recoveries of Ep after this procedure show very little sample-to-sample variation and are consistently between 45% and 55%, which is close to the maximum binding expected for the anti-Ep antibody. Coupled with the 7.4-fold concentration that this procedure affords, there is an overall increase in sensitivity of three- to fourfold, which makes this assay suitable for accurately measuring Ep levels in patients with below-average titers. Results with this magnetic bead assay indicate that accurate and reproducible estimates for Ep levels in the serum and plasma from healthy donors as well as from patients with hematologic disorders can be obtained. Titers of biologically active Ep in the sera from a group of patients with either leukemia or lymphoma were found to be elevated, and the values correlated well with titers of immunoreactive Ep measured in the Ep radioimmunoassay. Because of its specificity and high sensitivity, the magnetic bead assay is a valuable alternative to immunoassays for the measurement of elevated, normal, and even subnormal Ep levels in human serum and plasma.
منابع مشابه
Comparison of the hemagglutination inhibition assay kit for erythropoietin (ESF) with the fetal mouse liver cell bioassay in vitro.
The commercially available hemagglutination inhibition (HAI) assay kit for erythropoietin (ESF) was compared with the fetal mouse liver cell (FMLC) bioassay. No correlation was obtained ESF levels determined by both methods in a variety of pathologic sera. The HAI kit showed a great batch variability. Significant immunoreactivity was found in those fractions of a normal human serum and a human ...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملProduction of Erythropoietin-specific polyclonal Antibodies
Background: Erythropoietin, as a principal hormone promotes red blood cell production in bone marrow. Varieties of erythropoietin biosimilar are being produced by recombinant DNA technology in cell cultures. The detection or quantification of these molecules are being performed by diff erent methods which some of theme such as Western blot and enzymelinked immunosorbent assay (ELISA) require sp...
متن کاملModified method of erythropoietin (ESF) bioassay in vitro using mouse fetal liver cells. II. measurement of ESF in human serum.
A modification of the mouse fetal liver cell bioassay for erythropoietin (ESF) that allows quantitative detection of ESF in human serum is described. The modification consists of (1) correction for the effect of serum iron on 59Fe incorporation into heme and (2) the use of an "internal standard," i.e., a standard ESF preparation dissolved in the assayed test serum. As a result of this modificat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Blood
دوره 76 7 شماره
صفحات -
تاریخ انتشار 1990