External Fixation Using Femoral Less Invasive Stabilization System Plate in Tibial Proximal Metaphyseal Fracture

نویسندگان

  • Jingwei Zhang
  • Nabil Ebraheim
  • Ming Li
  • Xianfeng He
  • Jiayong Liu
  • Limei Zhu
  • Yihui Yu
چکیده

BACKGROUND The locking plates are often used for internal fixation of closed tibial fractures. The use of a locking plate as an external fixator is still controversial, particularly for closed fractures. The purpose of this study is to evaluate the results of external fixation using the femoral less invasive stabilization system (LISS) plate in proximal metaphyseal fractures of the tibia. METHODS We prospectively evaluated 35 patients (26 males and 9 females) with a mean age of 42 years (range, 21 to 62 years) who presented with fresh tibial proximal metaphyseal fractures. According to the AO Foundation and Orthopaedic Trauma Association (AO/OTA) classification, the fractures were identified as type 41-A2 in 18 cases and type 41-A3 in 17 cases, including 25 closed fractures and 10 open fractures. The femoral LISS plate was used to fix these fractures, which was placed on the anteromedial aspect of the tibia as an external fixator. The mean follow-up period was 18 months (range, 13 to 22 months). RESULTS All fractures healed in a mean time of 14 weeks (range, 10 to 20 weeks). There was no case of nonunion, deep infection, and loosening of screws and plates. One month after the appearance of cortical bridging on biplanar radiographs, the locking plate was removed within 3 minutes in the clinic without any difficulty. According to the Hospital for Special Surgery (HSS) knee scoring system and American Orthopaedic Foot & Ankle Society (AOFAS) ankle scoring system, the mean HSS score was 91 (range, 85 to 100) and 98 (range, 93 to 100), and the mean AOFAS score was 94 (range, 90 to 100) and 98 (range, 95 to 100) at 4 weeks postoperatively and final follow-up, respectively. CONCLUSIONS For proximal metaphyseal fracture of the tibia, external fixation using the femoral LISS plate is a safe and reliable technique with minimal complications and excellent outcomes. Its advantages include ease of performing the surgery, use of a less invasive technique, and convenience of plate removal after fracture healing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-Stage External Fixation Using a Locking Plate: Experience in 116 Tibial Fractures.

The authors report the results of 1-stage external fixation using a locking plate in 116 tibial fractures (85 closed and 31 open). The patients were followed for an average of 22 months. The mean duration of surgery was 42 minutes. The mean fracture healing time was 12 weeks for proximal, 20 weeks for shaft, 14 weeks for distal, and 24 weeks for multisegmental tibial fractures. Nonunion, deep i...

متن کامل

Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation.

The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic dist...

متن کامل

The use of tibial Less Invasive Stabilization System (LISS) plate [AO-ASIF] for the treatment of paediatric supracondylar fracture of femur: a case report

Paediatric supracondylar fractures of the femur are not common. The treatment options depend on the age of child, the site of the fracture, the pattern of injury and the surgeon's preference. We report a case of an 11-year old boy who sustained a comminuted displaced supracondylar fracture of the femur and was treated with indirect reduction and internal fixation with the Less Invasive Stabiliz...

متن کامل

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...

متن کامل

Minimally Invasive Plate Osteosynthesis (MIPO) in Long Bone Fractures – Biomechanics – Design – Clinical Results

Complex periarticular fractures of the long bones are difficult to treat. Classic intramedullary osteosynthesis do not provide a stable fixation (Wiss et al., 1986), while open reduction and rigid fixation by classic plates (recommended in the 60s-70s) is requiring large incisions with important deperiostation. Potential complications as infections, consolidation delays and construct damage due...