106CdWO4 crystal scintillator in coincidence with four crystals HPGe detector

نویسندگان

  • V. I. Tretyak
  • P. Belli
چکیده

An experiment to search for double beta processes in Cd by using cadmium tungstate crystal scintillator enriched in Cd (106CdWO4) in coincidence with the four crystals HPGe detector GeMulti is in progress at the STELLA facility of the Gran Sasso underground laboratory of INFN (Italy). The 106CdWO4 scintillator is viewed by a low-background photomultiplier tube through a lead tungstate crystal light-guide produced from deeply purified archaeological lead to suppress  quanta from the photomultiplier tube. Here we report the first results of the experiment after 3233 hours of the data taking. A few new improved limits on double beta processes in Cd are obtained, in particular T1/2 2+  8.4 × 10 yr at 90% C.L.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Construction of an Ultra-low-background 14 Germanium Crystal Array for High Efficiency and Coincidence Measurements

Physics experiments, environmental surveillance, and treaty verification techniques continue to require increased sensitivity for detecting and quantifying radionuclides of interest. This can be done by detecting a greater fraction of gamma emissions from a sample (higher detection efficiency) and reducing instrument backgrounds. A current effort for increased sensitivity in high resolution gam...

متن کامل

Influence of Depth of Interaction upon the Performance of Scintillator Detectors

The uncertainty in time of particle detection within a scintillator detector, characterised by the coincidence time resolution (CTR), is explored with respect to the interaction position within the scintillator crystal itself. Electronic collimation between two scintillator detectors is utilised to determine the CTR with depth of interaction (DOI) for different materials, geometries and wrappin...

متن کامل

Multidimensional Calibration of the EXOGAM Segmented Clover

The EXOGAM clover detector consists of four high-purity germanium (HPGe) crystals in a common cryostat. Each individual crystal is electrically segmented into four regions. We propose a method based on a multidimensional fitting procedure to calibrate the energy from the segments. This method could be used for any kind of segmented germanium detector. Its application to the EXOGAM clover is dis...

متن کامل

Digital Pulse Shape Analysis with Phoswich Detectors to Simplify Coincidence Measurements of Radioactive Xenon

The Comprehensive Nuclear-Test-Ban Treaty establishes a network of monitoring stations to detect radioactive xenon in the atmosphere from nuclear weapons testing. One such monitoring system is the Automated Radioxenon Sampler/Analyzer (ARSA) developed at Pacific Northwest National Laboratory, which uses a complex arrangement of separate beta and gamma detectors to detect beta-gamma coincidences...

متن کامل

Digital Timing Algorithm for High Purity Germanium Detectors

The next generation of γ-ray detector arrays will be composed of large volume high purity germanium (HPGE) detectors that are electronically segmented. These detectors will be able to track γ-rays as they Compton scatter within the crystal and between adjacent crystals, eliminating the need for Compton suppression detectors and improving angular resolution. The new arrays will have much higher ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013