Clinical feasibility of accelerated, high spatial resolution myocardial perfusion imaging.

نویسندگان

  • Robert Manka
  • Viton Vitanis
  • Peter Boesiger
  • Andreas J Flammer
  • Sven Plein
  • Sebastian Kozerke
چکیده

OBJECTIVES The aim of this study was to assess the clinical feasibility and diagnostic performance of an acceleration technique based on k-space and time (k-t) sensitivity encoding (SENSE) for rapid, high-spatial resolution cardiac magnetic resonance (CMR) myocardial perfusion imaging. BACKGROUND The assessment of myocardial perfusion is of crucial importance in the evaluation of patients with known or suspected coronary artery disease. CMR myocardial perfusion imaging performs favorably compared to single photon-emission computed tomography and offers higher spatial resolution, particularly when combined with scan acceleration techniques such as k-t SENSE. A previous study showed that k-t SENSE accelerated myocardial perfusion CMR with 5-fold acceleration is feasible and delivers high diagnostic accuracy for the detection of coronary artery disease. Higher acceleration factors have not been attempted clinically because of concerns over temporal blurring effects of the time-varying signal during contrast bolus passage. METHODS Twenty patients underwent myocardial perfusion CMR imaging using a 3.0-T whole-body CMR imager before diagnostic X-ray coronary angiography. Perfusion images were obtained using an extension of the k-t SENSE method using parallel imaging to double the spatial resolution of the k-t SENSE training images. This extension, termed k-t SENSE+, permitted 8-fold nominal scan acceleration and an in-plane spatial resolution of up to 1.1 x 1.1 mm(2). Perfusion scores were derived by 2 blinded observers for 16 myocardial segments and compared to quantitative analysis of X-ray coronary angiography. RESULTS CMR data were successfully obtained in all 20 patients. High diagnostic accuracy was achieved using CMR, as reflected by areas under the receiver-operator characteristic curve of 0.94 and 0.82 for detecting stenoses >50% and >75%, respectively. Observer agreement between 2 readers had a kappa value of 0.92. The areas under the receiver-operator characteristic curves for the left anterior descending, left circumflex, and right coronary artery territories with stenoses >50% were 0.75, 0.92, and 0.79, respectively. CONCLUSIONS Accelerated CMR perfusion imaging is clinically feasible and offers excellent diagnostic performance in detecting coronary stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Effect of Improving Spatial or Temporal Resolution on Image Quality and Quantitative Perfusion Assessment with k-t SENSE Acceleration in First-Pass CMR Myocardial Perfusion Imaging

k-t Sensitivity-encoded (k-t SENSE) acceleration has been used to improve spatial resolution, temporal resolution, and slice coverage in first-pass cardiac magnetic resonance myocardial perfusion imaging. This study compares the effect of investing the speed-up afforded by k-t SENSE acceleration in spatial or temporal resolution. Ten healthy volunteers underwent adenosine stress myocardial perf...

متن کامل

Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]

Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...

متن کامل

A comparison of high-resolution and standard cardiovascular magnetic resonance myocardial perfusion imaging for the detection of myocardial ischaemia

Background First pass myocardial perfusion imaging by CMR may permit the detection of myocardial ischaemia with greater accuracy than single photon emission computed tomography (SPECT). Technical developments have led to improvements in myocardial perfusion CMR, particularly through accelerated data acquisition methods. These permit the acquisition of data at higher spatial resolution than conv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 3 7  شماره 

صفحات  -

تاریخ انتشار 2010