[Clinical study on sweep-frequency tympanometry--data analysis using principal component analysis].

نویسنده

  • T Terada
چکیده

A sweep-frequency tympanometer has been developed to diagnose auditory ossicular lesions more precisely. This device measures acoustic middle ear features by changing the probe tone frequency continuously. The oscillator sweeps frequency of the probe tone from 200 to 2,500Hz 1.5 seconds. A microphone picks up the changes in the acoustic pressure and the phase in the external auditory meatus during the frequency change of the probe tone. These measurements are performed under pressures at -200 and 0 dapa, and differences of both the acoustic pressure and the phase between these two pressures are graphically displayed using a microcomputer. This device can also measure and digitally display the frequency (BHz) and the sound pressure (BdB) at the minimum point (B) of the sound pressure curve, the frequency (ZHz) at 0 crossing point (Z) of the sound pressure curve, and the frequency (PHz) and the phase difference (Pdeg) at the maximum point (P) of the phase curve. Normal ranges of these five values were obtained to establish diagnostic criteria from 200 normal ears. The normal values were as follows: BHz, 480 to 1,070Hz; BdB, -6.0 to -1.8dB; ZHz, 1,100 to 1,860Hz; PHz, 910 to 1,820Hz; and Pdeg, 16.3 to 47.9 degrees. Eight cases of ossicular dislocation and 14 cases of ossicular fixation, all of which had normal external auditory meatus and tympanic membrane, were evaluated based on these values. All the cases with ossicular dislocation and 12 cases out of 14 with ossicular fixation were correctly diagnosed.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of mineralization features and deep geochemical anomalies using a new FT-PCA approach

The analysis of geochemical data in frequency domain, as indicated in this research study, can provide new exploratory informationthat may not be exposed in spatial domain. To identify deep geochemical anomalies, sulfide zone and geochemical noises in Dalli Cu–Au porphyry deposit, a new approach based on coupling Fourier transform (FT) and principal component analysis (PCA) has beenused. The re...

متن کامل

Detection of Mo geochemical anomaly in depth using a new scenario based on spectrum–area fractal analysis

Detection of deep and hidden mineralization using the surface geochemical data is a challenging subject in the mineral exploration. In this work, a novel scenario based on the spectrum–area fractal analysis (SAFA) and the principal component analysis (PCA) has been applied to distinguish and delineate the blind and deep Mo anomaly in the Dalli Cu–Au porphyry mineralization area. The Dalli miner...

متن کامل

Prediction of mineral deposit model and identification of mineralization trend in depth using frequency domain of surface geochemical data in Dalli Cu-Au porphyry deposit

In this research work, the frequency domain (FD) of surface geochemical data was analyzed to decompose the complex geochemical patterns related to different depths of the mineral deposit. In order to predict the variation in mineralization in the depth and identify the deep geochemical anomalies and blind mineralization using the surface geochemical data for the Dalli Cu-Au porphyry deposit, a ...

متن کامل

Prediction of dispersed mineralization zone in depth using frequency domain of surface geochemical data

Discrimination of the blind and dispersed mineralization deposits is a challenging problem in geochemical exploration. The frequency domain (FD) of the surface geochemical data can solve this important issue. This new exploratory information can be achieved using the interpretation of FD of geochemical data, which is impossible in spatial domain. In this research work, FD of the surface geochem...

متن کامل

Standard and multifrequency tympanometry in normal and otosclerotic ears.

OBJECTIVES The primary goal of this study was to evaluate alternative tympanometric parameters for distinguishing normal middle ears from ears with otosclerosis. A secondary goal was to provide guidelines and normative data for interpreting multifrequency tympanometry obtained using the Virtual 310 immittance system. DESIGN Nine tympanometric measures were examined in 68 normal ears and 14 ea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Jibiinkoka Gakkai kaiho

دوره 92 6  شماره 

صفحات  -

تاریخ انتشار 1989