Beat-to-beat changes in stroke volume precede the general circulatory effects of mechanical ventilation: a case report

نویسندگان

  • N Nelson
  • B Janerot-Sjöberg
چکیده

BACKGROUND The haemodynamic as well as the ventilatory consequences of mechanical ventilation can be harmful in critically ill neonates. Newly developed ventilatory lung protective strategies are not always available immediately and in an acute situation the haemodynamic changes caused by mechanical ventilation can affect the oxygen delivery considerably. We report the case of a male neonate who was treated with conventional pressure-controlled mechanical ventilation because of respiratory distress and progressive respiratory acidosis resulting from meconium aspiration. Because of poor arterial oxygenation despite 100% inspired oxygen and increased ventilator settings, echocardiography was performed to exclude central haemodynamic reasons for low oxygen delivery. METHOD Doppler echocardiography was used for the measurement of stroke volume and cardiac output. Pulse oximetry and aortic blood pressure were monitored continuously. RESULTS Echocardiography revealed no cardiac malformations or signs of persistent fetal circulation. When inspiratory pressures and duration were increased, beat-to-beat variation in stroke volume preceded decay in cardiac output. Stroke volume variations and oxygen saturation values guided ventilator settings until extracorporal membrane oxygenation could be arranged for. After recovery and discharge 4 weeks later the boy is progressing normally. CONCLUSION Because oxygen delivery is dependent on both blood flow and arterial oxygen content, measurement of cardiac output as well as left heart oxygen saturation is a useful guide to optimizing oxygen delivery. This case report demonstrates how Doppler echocardiographic monitoring of beat-to-beat changes in stroke volume can be used to detect early negative haemodynamic effects of increased mechanical ventilation settings before cardiac output is affected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pressure-flow studies in man during the Valsalva maneuver with observations on the mechanical properties of the ascending aorta.

SUMMARY The pressure-gradient technique was used to obtain continuous measurements of both blood pressure and flow in the ascending aorta of eight normal subjects who were performing a standardized Valsalva maneuver. From these recordings the beat-to-beat changes in stroke volume, peak blood flow, peripheral vascular resistance, duration of ejection, and an index of total systolic duration were...

متن کامل

RV filling modulates LV function by direct ventricular interaction during mechanical ventilation.

During mechanical ventilation, phasic changes in systemic venous return modulate right ventricular output but may also affect left ventricular function by direct ventricular interaction. In 13 anesthetized, closed-chest, normal dogs, we measured inferior vena cava flow and left and right ventricular dimensions and output during mechanical ventilation, during an inspiratory hold, and (during apn...

متن کامل

Improved pressure contour analysis for estimating cardiac stroke volume using pulse wave velocity measurement

BACKGROUND Pressure contour analysis is commonly used to estimate cardiac performance for patients suffering from cardiovascular dysfunction in the intensive care unit. However, the existing techniques for continuous estimation of stroke volume (SV) from pressure measurement can be unreliable during hemodynamic instability, which is inevitable for patients requiring significant treatment. For t...

متن کامل

Quantification of the relationships between volume and intensity of exhaustive treadmill running in active young men

ABSTRACT: Aim: Quantifying the relationship between volume and intensity as key components of training is a precise manner that is complicated for most coaches.  The aim of this study was to quantify the inverse relationships between training volume and intensity during exhaustive treadmill running among active young men. Method and Material: 32 active young men aged 21 years selected as subjec...

متن کامل

Estimation of preload recruitable stroke work relationship by a single-beat technique in humans.

The slope of the preload recruitable stroke work relationship (M(w)) is a highly linear, load-insensitive contractile index. To investigate whether M(w) can be determined from a single steady-state beat, 45 patients were studied during cardiac catheterization. Single-beat M(w) (SBM(w)) was calculated directly from the baseline stroke work and baseline left ventricular (LV) end-diastolic volume ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2001