AbstractID: 9840 Title: Dual Energy Chest Radiography

ثبت نشده
چکیده

ID: 9840 Title: Dual Energy Chest Radiography Dual Energy Chest Radiography Visual detection of pulmonary abnormalities on screen-film radiographs is notoriously unreliable. Digital radiography can improve diagnostic accuracy due to its greater latitude, improved local contrast and more consistent image quality compared to screen-film systems. In addition to facilitating detection by traditional visual inspection of the image, digital imaging enables advanced techniques such as dual energy subtraction and temporal subtraction, which can improve diagnostic accuracy further, especially for subtle lesions such as early lung cancer. Dual energy subtraction radiography exploits the energy dependence of x-ray attenuation by different tissues. By subtracting the ribs and other bones from the image and displaying them separately, energy subtraction (ES) radiography can improve diagnostic accuracy. Two fundamentally different methods have been used. One involves the use of sequential x-ray exposures in rapid succession, at different kVp settings. This approach has the advantage of more optimal separation of high and low energy components. However, the inevitable time delay between the first and second exposure can introduce misregistration artifacts in clinical practice. The second approach involves the use of a single exposure, which is recorded by two receptors separated by a filter. In the case of a CR ES chest unit, a single exposure is made, using standard technique. Instead of a single storage phosphor plate, two plates are used, with a copper filter sandwiched between them. In all, three PA images are produced: the standard image, the soft tissue image, and the bone image. Recently, a new energy subtraction chest unit has been developed that uses a Csi/Amorphous silicon flat panel detector. This unit employs two exposures at different energy levels, with a 200msec interval. Although some motion artifacts are present around vascular structures, pixel shifting and noise reduction software effectively minimizes them. Temporal Subtraction Chest Radiography Digital radiography allows various types of image enhancement to be performed, but techniques that improve the visibility of abnormal findings also tend to emphasize certain features of normal anatomy. In the case of patients who have had a previous chest radiograph, an opportunity exists to enhance selectively areas of interval change, including regions with new or altered pathology, by using the previous radiographs as a subtraction mask. The temporal subtraction technique involves automated two-dimensional warping and registration of a previous with a current chest radiograph in order to produce a "difference image" in which unchanged areas appear as uniform grey while new opacities appear as isolated dark foci that stand out from the uniform background. One of the unique advantages of temporal subtraction is that it can highlight areas of subtle change that may not appear obviously abnormal when viewed in isolation. Its ability to improve detection of a broad range of abnormalities, including nodules, infiltrative opacities, and even local pulmonary perfusion deficit alterations, are important advantages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dual energy subtraction chest radiography and traditional chest X-rays in the detection of pulmonary nodules.

BACKGROUND Dual energy subtraction (DES) radiography is a powerful but underutilized technique which aims to improve the diagnostic value of an X-ray by separating soft tissue from bones, producing two different images. Compared to traditional chest X-rays, DES requires exposure to higher doses of radiation but may achieve higher accuracy. The objective of this study was to assess the clinical ...

متن کامل

Evaluation of a commercial cardiac motion phantom for dual‐energy chest radiography

Misregistration due to cardiac motion causes artifacts in two-exposure dual-energy subtraction images, in both the soft-tissue-only image and the bone-only image. Two previous investigations have attempted to avoid misregistration artifacts by using cardiac gating of the first and second exposures. The severity of misregistration was affected by the heart rate, the time interval between the low...

متن کامل

Advances in Digital Chest Radiography: Dual Energy, CAD, and Digital Tomosynthesis

While recent advances in radiologic imaging have focused on CT and MRI technology, progress in digital radiographic techniques has also had significant impact on our ability to evaluate cardiothoracic disease. A number of publications have established the improved image quality of digital imaging systems over conventional film techniques [1]. While image quality has clearly improved with digita...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

[Evaluation of improvement of the detection of interstitial lung diseases by using the dual-energy subtraction radiography method of a flat-panel detector system].

We investigated and evaluated the detection of simulated lesions in various interstitial lung diseases using the dual-energy subtraction radiography method and flat-panel detector (FPD) images. We obtained a FPD system (GE Revolution XR/d), and employed dual-energy 60 kV and 130 kV exposure techniques. Three types of lung lesions, namely, micro-nodule, ground-glass, and honeycomb patterns were ...