Dobutamine stress echocardiography versus quantitative technetium-99m sestamibi SPECT for detecting residual stenosis and multivessel disease after myocardial infarction.
نویسندگان
چکیده
OBJECTIVE To compare the relative accuracy of dobutamine stress echocardiography (DSE) and quantitative technetium-99m sestamibi single photon emission computed tomography (mibi SPECT) for detecting infarct related artery stenosis and multivessel disease early after acute myocardial infarction. DESIGN Prospective study. SETTING University hospital. METHODS 75 patients underwent simultaneous DSE and mibi SPECT at (mean (SD)) 5 (2) days after a first acute myocardial infarct. Quantitative coronary angiography was performed in all patients after imaging studies. RESULTS Significant stenosis (> 50%) of the infarct related artery was detected in 69 patients. Residual ischaemia was identified by DSE in 55 patients and by quantitative mibi SPECT in 49. The sensitivity of DSE and mibi SPECT for detecting significant infarct related artery stenosis was 78% and 70%, respectively, with a specificity of 83% for both tests. The combination of DSE and mibi SPECT did not change the specificity (83%) but increased the sensitivity to 94%. Mibi SPECT was more sensitive than DSE for detecting mild stenosis (73% v 9%; p = 0.008). The sensitivity of DSE for detecting moderate or severe stenosis was greater than mibi SPECT (97% v 74%; p = 0.007). Wall motion abnormalities with DSE and transient perfusion defects with mibi SPECT outside the infarction zone were sensitive (80% v 67%; NS) and highly specific (95% v 93%; NS) for multivessel disease. CONCLUSIONS DSE and mibi SPECT have equivalent accuracy for detecting residual infarct related artery stenosis of >/= 50% and multivessel disease early after acute myocardial infarction. DSE is more predictive of moderate or severe infarct related artery stenosis. Combined imaging only improves the detection of mild stenosis.
منابع مشابه
Assessment of myocardial perfusion and contractile function by inotropic stress Tc-99m sestamibi SPECT imaging and echocardiography for optimal detection of multivessel coronary artery disease.
OBJECTIVE To assess whether inotropic stress myocardial perfusion imaging, echocardiography, or a combination of the two could enhance the detection of multivessel disease, over and above clinical and exercise electrocardiographic data. DESIGN 100 consecutive patients investigated by exercise electrocardiography and diagnostic coronary arteriography underwent simultaneous inotropic stress Tc-...
متن کاملPrognostic value of dobutamine stress technetium-99m-sestamibi single-photon emission computed tomography myocardial perfusion imaging: stratification of a high-risk population.
OBJECTIVES This work was undertaken to define the intrinsic cardiac risk of the patient population referred for dobutamine stress perfusion imaging and to determine whether dobutamine technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography (SPECT) imaging is capable of risk stratification in this population. BACKGROUND In animal models, dobutamine attenuates the myocardi...
متن کاملValue of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging.
OBJECTIVES The purpose of this study was to determine how frequently and for what reasons the addition of electrocardiographically gated technetium-99m (Tc-99m) sestamibi single-photon emission computed tomographic (SPECT) images add value to nongated SPECT perfusion images. BACKGROUND Electrocardiographic gating of Tc-99m sestamibi SPECT images permits assessment of regional and global left ...
متن کاملEvaluation by quantitative 99m-technetium MIBI SPECT and echocardiography of myocardial perfusion and wall motion abnormalities in patients with dobutamine-induced ST-segment elevation.
ST-segment elevation during exercise testing has been attributed to myocardial ischemia and wall motion abnormalities (WMA). However, the functional significance of ST-segment elevation during dobutamine stress testing (DST) has not been evaluated in patients referred for diagnostic evaluation of myocardial ischemia. DST (up to 40 micrograms/kg/min) with simultaneous echocardiography and techne...
متن کاملDetection and clinical usefulness of a biphasic response during exercise echocardiography early after myocardial infarction.
OBJECTIVE The aim of this study was to determine the accuracy of exercise echocardiography (EE) for detecting infarct-related artery (IRA) stenosis and predicting functional recovery early after acute myocardial infarction (AMI). BACKGROUND Dobutamine stress echocardiography is widely used for identifying jeopardized myocardium. The clinical usefulness of a biphasic response detected during E...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 86 5 شماره
صفحات -
تاریخ انتشار 2001