OBJECTIVES To evaluate area- and gender-related differences in the soft tissue thickness of potential areas for installing miniscrews in the buccal-attached gingiva and the palatal masticatory mucosa. MATERIALS AND METHODS The sample consisted of 61 Korean young adults. An ultrasonic gingival-thickness meter was used to measure the soft-tissue thickness in the buccal-attached gingiva just adjacent to the mucogingival junction of the upper and lower arches and 4 mm and 8 mm below the gingival crest in the palatal masticatory mucosa. Independent t-test, paired t-test, and one-way analysis of variance were used for statistical analysis. RESULTS Buccal-attached gingiva thickness in the upper arch was significantly greater in men than in women, but buccal-attached gingiva thickness in the lower arch and palatal masticatory mucosa thickness 4 and 8 mm below the gingival crest did not show gender differences. Significantly thicker soft tissue occurred in the anterior areas in the upper arch and in the posterior areas in the lower arch. In the palatal masticatory mucosa, significantly thicker soft tissue was found 4 mm below the gingival crest in the anterior areas and 8 mm below the gingival crest in the posterior areas. The areas between the canines and the premolars showed higher values than other areas 4 mm below the gingival crest. However, the soft-tissue thickness 8 mm below the gingival crest showed a progressive increase from the anterior to the posterior areas. CONCLUSION Measurements of the soft-tissue thickness using an ultrasonic device could help practitioners select the proper orthodontic miniscrew in daily clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risks and complications of orthodontic miniscrews.

The risks associated with miniscrew placement should be clearly understood by both the clinician and the patient. Complications can arise during miniscrew placement and after orthodontic loading that affect stability and patient safety. A thorough understanding of proper placement technique, bone density and landscape, peri-implant soft-tissue, regional anatomic structures, and patient home car...

متن کامل

Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tub...

متن کامل

Soft-tissue and cortical-bone thickness at orthodontic implant sites.

INTRODUCTION To obtain sufficient stability of implants, the thickness of the soft tissue and the cortical bone in the placement site must be considered. However, the literature contains few anatomical studies of orthodontic implants. METHODS To measure soft-tissue and cortical-bone thicknesses, maxillae from 23 Korean cadavers were decalcified, and buccopalatal cross-sectional specimens were...

متن کامل

Root perforation associated with the use of a miniscrew implant used for orthodontic anchorage: a case report.

AIM To highlight one of the possible complications associated with the inter-radicular placement of orthodontic miniscrews. SUMMARY This case report describes the endodontic treatment and surgical repair of an iatrogenic root perforation involving a maxillary first molar tooth following the placement of an orthodontic miniscrew placed for anchorage purposes in the treatment of an adult patien...

متن کامل

The Effects of Different Miniscrew Thread Designs and Force Directions on Stress Distribution by 3-dimensional Finite Element Analysis

STATEMENT OF THE PROBLEM The use of miniscrew as an absolute anchorage device in clinical orthodontics is growing increasingly. Many attempts have been made to reduce the size, to improve the design, and to increase the stability of miniscrew. PURPOSE The purpose of this study was to determine the effects of different thread shapes and force directions of orthodontic miniscrew on stress distr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Angle orthodontist

دوره 78 3  شماره 

صفحات  -

تاریخ انتشار 2008