Targeting Moderate and Severe Male Stress Urinary Incontinence With Adjustable Male Slings and the Perineal Artificial Urinary Sphincter: Focus on Perioperative Complications and Device Explantations

نویسندگان

  • Alexander Kretschmer
  • Tanja Hüsch
  • Frauke Thomsen
  • Dominik Kronlachner
  • Alice Obaje
  • Ralf Anding
  • Tobias Pottek
  • Achim Rose
  • Roberto Olianas
  • Alexander Friedl
  • Wilhelm Hübner
  • Roland Homberg
  • Jesco Pfitzenmaier
  • Fabian Queissert
  • Carsten M Naumann
  • Carola Wotzka
  • Torben Hofmann
  • Roland Seiler
  • Axel Haferkamp
  • Ricarda M Bauer
چکیده

PURPOSE To analyze perioperative complications and postoperative explantation rates for selected readjustable male sling systems and the perineal single-cuff artificial urinary sphincter (AUS) in a large, contemporary, multi-institutional patient cohort. METHODS Two hundred eighty-two male patients who underwent implantation between 2010 and 2012 in 13 participating institutions were included in the study (n=127 adjustable male sling [n=95 Argus classic, n=32 Argus T], n=155 AUS). Perioperative characteristics and postoperative complications were analyzed. The explantation rates of the respective devices were assessed using the Fisher exact test and the Mann-Whitney U-test. A Kaplan-Meier curve was generated. Potential features associated with device explantation were analyzed using a multiple logistic regression model (P<0.05). RESULTS We found significantly increased intraoperative complication rates after adjustable male sling implantation (15.9% [adjustable male sling] vs. 4.2% [AUS], P=0.003). The most frequent intraoperative complication was bladder perforation (n=17). Postoperative infection rates did not vary significantly between the respective devices (P=0.378). Device explantation rates were significantly higher after AUS implantation (9.7% [adjustable male sling] vs. 21.5% [AUS], P=0.030). In multivariate analysis, postoperative infection was a strong independent predictor of decreased device survival (odds ratio, 6.556; P=0.001). CONCLUSIONS Complication profiles vary between adjustable male slings and AUS. Explantation rates are lower after adjustable male sling implantation. Any kind of postoperative infections are independent predictors of decreased device survival. There is no significant effect of the experience of the implanting institution on device survival.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Male Stress Urinary Incontinence: A Review of Surgical Treatment Options and Outcomes

Introduction and Objective. Iatrogenic male stress urinary incontinence (SUI) affects a percentage of men undergoing urologic procedures with a significant impact on quality of life. The treatment of male SUI has evolved significantly with multiple current options for treatment available. The current paper discusses preoperative evaluation of male SUI, available surgical options with reported o...

متن کامل

Contemporary surgical devices for male stress urinary incontinence: a review of technological advances in current continence surgery

Male stress urinary incontinence (SUI) remains a debilitating condition that adversely impacts all domains of quality of life and is associated with significant social stigma and health economic burden. The incidence of post-prostatectomy urinary incontinence (PPI) depends on the definition of urinary incontinence and the length of patient follow up. In patients with persistent PPI following fa...

متن کامل

Male incontinence and the transobturator approach: An analysis of current outcomes

OBJECTIVES To provide an analysis of the outcomes in patients who have a suburethral sling placed using the transobturator approach for the treatment of stress urinary incontinence after radical prostatectomy, because data in this specific area remain limited, and recent changes in male sling surgery might improve the efficacy in men with moderate or mild incontinence. METHODS We evaluated th...

متن کامل

Current interventional management of male stress urinary incontinence following urological procedures.

INTRODUCTION Despite improvements in surgical techniques and implementation of minimally invasive procedures, male stress urinary incontinence affects a substantial number of patients after prostatic surgery. In response to increasing demand of optimal treatment modality, new alternatives to artificial urinary sphincter have recently been introduced. This review summarises the therapeutic surgi...

متن کامل

Virtue Quadratic Male Sling for stress incontinence—surgical guide for placement and delayed revision

The algorithm for surgical management of post prostatectomy incontinence classically includes male slings and artificial urinary sphincter (AUS) placement. The Virtue Quadratic Male Sling was designed to provide both urethral elevation and prepubic compression making it a viable option for a wider spectrum of incontinent men whose symptoms range from mild to severe. With a focus on two key step...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2017