Conducting polymer-coated electrode as a reference/counter electrode in an organic phase and its application to a two-electrode type thin-layer cell for voltammetry at the liquid | liquid interface.

نویسندگان

  • Yumi Yoshida
  • Satoshi Yamaguchi
  • Kohji Maeda
چکیده

An indium tin oxide glass electrode coated with poly(3,4-ethylenedioxythiophene), PEDOT, PEDOT-ITOE, was proposed as an electrode workable as both a reference electrode and a counter one, a reference/counter electrode, in an organic phase and applied to a thin-layer cell of a two-electrode system for voltammetry at the liquid | liquid interface. By oxidizing the PEDOT film by 50% and doping a supporting electrolyte anion in an organic phase into the PEDOT film, a suitable depolarization was realized at the PEDOT | organic phase interface. The partially oxidized PEDOT-ITOE showed a Nerntian response to the supporting electrolyte anion concentration in the organic phase. The electrode potential was stable within +/-3 mV for 12 h, and showed a consistent value among the PEDOT-ITOEs prepared under the same procedure (the error range was about 7 mV, n = 8).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved thin-layer electrolysis cell for ion transfer at the liquid|liquid interface using a conducting polymer-coated electrode.

This article reviews the development of a thin-layer electrolysis cell with both a thin aqueous phase and a thin organic phase for ion transfer at the liquid|liquid interface for the absolute determination of a redox-inactive ion. In particular, an improvement of the cell performance by using a conducting polymer-coated electrode in the organic phase is discussed. The applicability of the thin-...

متن کامل

Development of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design

In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...

متن کامل

Electrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode

In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...

متن کامل

Covalent Modification of Glassy Carbon Electrode with an Imidazolium based Methoxysilyl Ionic Liquid Nanoparticles: Application in Determination of Redox System

Glassy carbon (GC) is the most commonly used carbon-based electrode in the analytical laboratory. Because of the high background current and low electrode response, modification of this electrode can be done by various materials and techniques. An ionic liquid (IL), 1-methyl-3-(3-trimethoxysilyl propyl) imidazoliumbis (trifluoromethylsulfonyl) imide, was covalently cross linked onto the GC surf...

متن کامل

Electrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode

In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2010