Quantitative Estimation of the Influence of External Vibrations on the Measurement Error of a Coriolis Mass-flow Meter
نویسندگان
چکیده
In this paper the quantitative influence of external vibrations on the measurement value of a Coriolis Mass-Flow Meter for low flows is investigated, with the eventual goal to reduce the influence of vibrations. Model results are compared with experimental results to improve the knowledge on how external vibrations affect the measurement error. A Coriolis Mass-Flow Meter (CMFM) is an active device based on the Coriolis force principle for direct mass-flow measurements, independent of fluid properties, with a high accuracy, range-ability and repeatability. Besides the effect of the mass-flow on the mode shape of the tube, external vibrations can introduce motions that cannot be distinguished from the Coriolis force induced motion, thus introducing a measurement error. From a multi-axis flexible body model, the transfer function between external vibrations (e.g. floor vibrations) and the flow error, including the active filter characteristics, is derived. The floor vibrations are characterised with a PSD. Integrating the transfer function times the PSD over the whole frequency range results in an RMS flow error estimate. In an experiment predefined vibrations are applied on the casing of the CMFM (white noise spectra and VC norm spectra) and the error is determined. The experimental results corresponds with the model results. The agreement between model and measurements implies firstly that the influence of any floor vibration spectrum on the flow error, can be estimated and secondly that the performance of different CMFM designs can be compared and optimised by shaping their respective transfer functions.
منابع مشابه
A Sub-Optimal Look-Up Table Based on Fuzzy System to Enhance the Reliability of Coriolis Mass Flow Meter
Coriolis mass flow meters are one of the most accurate tools to measure the mass flow in the industry. However, two-phase mode (gas-liquid) may cause severe operating difficulties as well as decreasing certitude in measurement. This paper presents a method based on fuzzy systems to correct the error and improve the reliability of these sensors in the presence of two-phase model fluid. Definite ...
متن کاملAn Advanced State Estimation Method Using Virtual Meters
- Power system state estimation is a central component in energy management systems of power system. The goal of state estimation is to determine the system status and power flow of transmission lines. This paper presents an advanced state estimation algorithm based on weighted least square (WLS) criteria by introducing virtual meters. For each bus of network, except slack bus, a virtual meter...
متن کاملNumerical modeling of three-phase flow through a Venturi meter using the LSSVM algorithm
One of the challenging problems in the Oil & Gas industry is accurate and reliable multiphase flow rate measurement in a three-phase flow. Application of methods with minimized uncertainty is required in the industry. Previous developed correlations for two-phase flow are complex and not capable of three-phase flow. Hence phase behavior identification in different conditions to designing and mo...
متن کاملCoriolis Flow meter: A Review from 1989 to 2014
A consolidation of literature indicating the advances in the field of mass flow measurement is presently not available. Last published review paper on Coriolis mas flow meter (CFM) was in 2006. This work is an attempt is made to summarize the available works on Coriolis mass flow meter. The literature is classified into three major groups. The first group gives the summary of construction and t...
متن کاملThe impact of body mass index on the external dose rate from patients treated with radioiodine-131: A preliminary study
Introduction: The relation between patient Body Mass Index (BMI) and the external dose rate of thyroid cancer patients treated with 131I has been investigated. Methods: A total of 183 patients treated with 131I were selected randomly and divided according to their administrated activity into three groups: 3.7GBq, 5.5GBq and 7.4GBq. They were also stratified into three gro...
متن کامل