Multi-scale Image Fusion Between Pre-operative Clinical CT and X-ray Microtomography of Lung Pathology
نویسندگان
چکیده
Computational anatomy allows the quantitative analysis of organs in medical images. However, most analysis is constrained to the millimeter scale because of the limited resolution of clinical computed tomography (CT). X-ray microtomography (μCT) on the other hand allows imaging of ex-vivo tissues at a resolution of tens of microns. In this work, we use clinical CT to image lung cancer patients before partial pneumonectomy (resection of pathological lung tissue). The resected specimen is prepared for μCT imaging at a voxel resolution of 50 μm (0.05 mm). This high-resolution image of the lung cancer tissue allows further insides into understanding of tumor growth and categorization. For making full use of this additional information, image fusion (registration) needs to be performed in order to re-align the μCT image with clinical CT. We developed a multiscale non-rigid registration approach. After manual initialization using a few landmark points and rigid alignment, several levels of non-rigid registration between down-sampled (in the case of μCT) and up-sampled (in the case of clinical CT) representations of the image are performed. Any non-lung tissue is ignored during the computation of the similarity measure used to guide the registration during optimization. We are able to recover the volume differences introduced by the resection and preparation of the lung specimen. The average (± std. dev.) minimum surface distance between μCT and clinical CT at the resected lung surface is reduced from 3.3 ± 2.9 (range: [0.1, 15.9]) to 2.3 mm ± 2.8 (range: [0.0, 15.3]) mm. This is a significant improvement with p < 0.001 (Wilcoxon Signed Rank Test). The alignment of clinical CT with μCT will allow further registration with even finer resolutions of μCT (up to 10 μm resolution) and ultimately with histopathological microscopy images for further macro to micro image fusion that can aid medical image analysis.
منابع مشابه
Pericardium Based Model Fusion of CT and Non-contrasted C-arm CT for Visual Guidance in Cardiac Interventions
Minimally invasive transcatheter cardiac interventions are being adopted rapidly to treat a range of cardiovascular diseases. Pre-operative imaging, e.g., computed tomography (CT), plays an important role in surgical planning and simulation of cardiac interventions. Overlaying a 3D cardiac model extracted from pre-operative images onto real-time fluoroscopic images provides valuable visual guid...
متن کاملMicrotomography and Pore-Scale Modeling of Two-Phase Fluid Distribution
Synchrotron-based X-ray microtomography (micro CT) at the Advanced Light Source (ALS) line 8.3.2 at the Lawrence Berkeley National Laboratory produces threedimensional micron-scale-resolution digital images of the pore space of the reservoir rock along with the spacial distribution of the fluids. Pore-scale visualization of carbon dioxide flooding experiments performed at a reservoir pressure d...
متن کاملPercutaneous fusion of the sacroiliac joint with hollow modular anchorage screws: clinical and radiological outcome.
We reviewed 15 consecutive patients, 11 women and four men, with a mean age of 48.7 years (37.3 to 62.6), who between July 2004 and August 2007 had undergone percutaneous sacroiliac fusion using hollow modular anchorage screws filled with demineralised bone matrix. Each patient was carefully assessed to exclude other conditions and underwent pre-operative CT and MR scans. The diagnosis of sympt...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملEmpirical correlation for porosity deduction from X-ray computed tomography (CT)
For obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as X-ray computed tomography, CT, seems to be precise and accurate. Porosity is deducted from the CT image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. More than one hundred samples with carbonate li...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/1702.08155 شماره
صفحات -
تاریخ انتشار 2017