Tumor and red bone marrow dosimetry: comparison of methods for prospective treatment planning in pretargeted radioimmunotherapy

نویسندگان

  • Wietske Woliner-van der Weg
  • Rafke Schoffelen
  • Robert F Hobbs
  • Martin Gotthardt
  • David M Goldenberg
  • Robert M Sharkey
  • Cornelis H Slump
  • Winette TA van der Graaf
  • Wim JG Oyen
  • Otto C Boerman
  • George Sgouros
  • Eric P Visser
چکیده

BACKGROUND Red bone marrow (RBM) toxicity is dose-limiting in (pretargeted) radioimmunotherapy (RIT). Previous blood-based and two-dimensional (2D) image-based methods have failed to show a clear dose-response relationship. We developed a three-dimensional (3D) image-based RBM dosimetry approach using the Monte Carlo-based 3D radiobiological dosimetry (3D-RD) software and determined its additional value for predicting RBM toxicity. METHODS RBM doses were calculated for 13 colorectal cancer patients after pretargeted RIT with the two-step administration of an anti-CEA × anti-HSG bispecific monoclonal antibody and a (177)Lu-labeled di-HSG-peptide. 3D-RD RBM dosimetry was based on the lumbar vertebrae, delineated on single photon emission computed tomography (SPECT) scans acquired directly, 3, 24, and 72 h after (177)Lu administration. RBM doses were correlated to hematologic effects, according to NCI-CTC v3 and compared with conventional 2D cranium-based and blood-based dosimetry results. Tumor doses were calculated with 3D-RD, which has not been possible with 2D dosimetry. Tumor-to-RBM dose ratios were calculated and compared for (177)Lu-based pretargeted RIT and simulated pretargeted RIT with (90)Y. RESULTS 3D-RD RBM doses of all seven patients who developed thrombocytopenia were higher (range 0.43 to 0.97 Gy) than that of the six patients without thrombocytopenia (range 0.12 to 0.39 Gy), except in one patient (0.47 Gy) without thrombocytopenia but with grade 2 leucopenia. Blood and 2D image-based RBM doses for patients with grade 1 to 2 thrombocytopenia were in the same range as in patients without thrombocytopenia (0.14 to 0.29 and 0.11 to 0.26 Gy, respectively). Blood-based RBM doses for two grade 3 to 4 patients were higher (0.66 and 0.51 Gy, respectively) than the others, and the cranium-based dose of only the grade 4 patient was higher (0.34 Gy). Tumor-to-RBM dose ratios would increase by 25% on average when treating with (90)Y instead of (177)Lu. CONCLUSIONS 3D dosimetry identifies patients at risk of developing any grade of RBM toxicity more accurately than blood- or 2D image-based methods. It has the added value to enable calculation of tumor-to-RBM dose ratios.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone marrow radiation dosimetry of high dose 131I treatment in differentiated thyroid carcinoma patients

Background: Radiation absorbed dose to the red bone marrow, a critical organ in the therapy of thyroid carcinoma, is generally kept below 2 Gy for non-myeloablative therapies. The aim of this study was to calculate bone marrow radiation dose by using MIRDOSE3 package program and to optimize the safe limit of activity to be administered to the thyroid cancer patients. Materials and Methods: In t...

متن کامل

Protein in Patients with Gastrointestinal Malignancies Patient-Specific Dosimetry of Pretargeted Radioimmunotherapy Using CC49 Fusion

J Nucl Med. F. Meredith Sui Shen, Andres Forero, Albert F. LoBuglio, Hazel Breitz, M.B. Khazaeli, Darrell R. Fisher, Wenquan Wang and Ruby Protein in Patients with Gastrointestinal Malignancies Patient-Specific Dosimetry of Pretargeted Radioimmunotherapy Using CC49 Fusion http://jnm.snmjournals.org/content/46/4/642 This article and updated information are available at: http://jnm.snmjournals.or...

متن کامل

Establishment of the In Vivo Efficacy of Pretargeted Radioimmunotherapy Utilizing Inverse Electron Demand Diels-Alder Click Chemistry.

The pretargeting system based on the inverse electron demand Diels-Alder reaction (IEDDA) between trans-cyclooctene (TCO) and tetrazine (Tz) combines the favorable pharmacokinetic properties of radiolabeled small molecules with the affinity and specificity of antibodies. This strategy has proven to be an efficient method for the molecularly targeted delivery of pharmaceuticals, including isotop...

متن کامل

Bone marrow dosimetry using 124I-PET.

UNLABELLED Bone marrow is usually dose-limiting for radioimmunotherapy. In this study, we directly estimated red marrow activity concentration and the self-dose component of absorbed radiation dose to red marrow based on PET/CT of 2 different (124)I-labeled antibodies (cG250 and huA33) and compared the results with plasma activity concentration and plasma-based dose estimates. METHODS Two gro...

متن کامل

Science Briefs from the SNMMI Annual Meeting.

Theranostic RIT in CRC Researchers from Memorial Sloan– Kettering Cancer Center (New York, NY) and the Massachusetts Institute of Technology (Cambridge, MA) reported on continuing small animal studies with curative theranostic pretargeted 177LuDOTAT-Bn radioimmunotherapy (PRIT) in GPA33-expressing colorectal cancer. Mice with established SW1222 subcutaneous xenografts underwent treatment with 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015