Sidestream dark field images of the microcirculation: intra-observer reliability and correlation between two semi-quantitative methods for determining flow
نویسندگان
چکیده
BACKGROUND Since analysis of Sidestream Dark Field images still requires subjective interpretation, we wanted to determine intra-observer repeatability and to estimate the correlation between different evaluation methods. METHODS Fifty-four Sidestream Dark Field videos were analyzed twice by the same blinded observer using validated software. Vessels were detected, generating the parameter Total Vessel Density (TVD), and flow was determined by (i) classifying each vessel separately, generating the parameters Perfused Vessel Density (PVD) and Proportion of Perfused Vessels (PPV), and by (ii) the "Boerma" method, generating a Microvascular Flow Index (MFI) by quadrants. RESULTS Intraclass Correlation Coefficients (ICCs) were above 0.9 for TVD and above 0.8 for PDV and PPV. MFIby quadrants had the lowest reliability (ICC = 0.52 for capillaries and ICC = 0.59 for all vessels), significantly lower than for PVD (ICC = 0.89, p < 0.001 for capillaries and ICC = 0.90, p < 0.001 for all vessels) and PPV (ICC = 0.82, p = 0.003 for capillaries and ICC = 0.83, p = 0.01 for all vessels). Correlation coefficient (r) between PPV and MFIby quadrants corrected for measurement error was 0.39 (0.10 - 0.64) for capillaries and 1.01 (0.85 - 1.16) for all vessels. CONCLUSIONS Intra-observer reliability for full evaluation of Sidestream Dark Field images was good for vessel detection and for flow classification but significantly poorer for the faster "Boerma" method. Furthermore, the Boerma method is likely to estimate different aspects of capillary flow than do the standard methods.
منابع مشابه
Sidestream Dark Field Imaging of the Microcirculation to Assess Preeclampsia Microvascular Dysfunction
Background Development of predictive models of preeclampsia has only yielded modest results. We hypothesized that impaired indices of microcirculatory function could be detected using sidestream dark field imaging. The objective of this study was to examine microvascular function in women at high risk for preeclampsia at mid-gestation. Methods Women between 16 and 22 weeks of gestation were s...
متن کاملComparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment
Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...
متن کاملOrthogonal Polarization Spectral (OPS)/Sidestream dark field (SDF) imaging: a new method for the observation of the microcirculation in pediatrics
Microcirculation plays an important role both in physiological and pathophysiological states. Early recognition of changes in microcirculation is crucial for starting early therapeutic intervention and reversing the organ failure. Orthogonal polarization spectral (OPS) and Sidestream dark field imaging (SDF) are relatively new noninvasive methods that allow direct visualisation of the microcirc...
متن کاملA comparison of the quality of image acquisition between the incident dark field and sidestream dark field video-microscopes
BACKGROUND The 'Cytocam' is a third generation video-microscope, which enables real time visualisation of the in vivo microcirculation. Based upon the principle of incident dark field (IDF) illumination, this hand held computer-controlled device was designed to address the technical limitations of its predecessors, orthogonal polarization spectroscopy and sidestream dark field (SDF) imaging. In...
متن کاملارزیابی دقت نرم افزار کنتراست معکوس در رادیوگرافی دیجیتال جهت تشخیص شکستگی عمودی ریشه دندان (in vitro)
Background and Aims: Diagnosis of vertical root fractures often poses a clinical dilemma. Diagnosis of VRF in intraoral radiographs, except in cases where the beam is perpendicular to the direction of fracture is difficult. Misdiagnosis often leads to wrong decisions about the design of teeth future treatment plan. The aim of this study was to determine the diagnostic accuracy of reverse cont...