Diagnostic ability of hand-held echocardiography in ventilated critically ill patients

نویسندگان

  • Philippe Vignon
  • Catherine Chastagner
  • Bruno François
  • Jean-François Martaillé
  • Sandrine Normand
  • Michel Bonnivard
  • Hervé Gastinne
چکیده

STUDY OBJECTIVES To compare the diagnostic capability of recently available hand-held echocardiography (HHE) and of conventional transthoracic echocardiography (TTE) used as a gold standard in critically ill patients under mechanical ventilation. DESIGN A prospective and descriptive study. SETTING The general intensive care unit of a teaching hospital. PATIENTS All mechanically ventilated patients requiring a TTE study with a full-feature echocardiographic platform (Sonos 5500; Philips Medical Systems, Andover, MA, USA) also underwent an echocardiographic examination using a small battery-operated device (33 x 23 cm2, 3.5 kg) (Optigo; Philips Medical Systems). INTERVENTIONS Each examination was performed independently by two intensivists experienced in echocardiography and was interpreted online. For each patient, the TTE videotape was reviewed by a cardiologist experienced in echocardiography and the final interpretation was used as a reference diagnosis. RESULTS During the study period, 106 TTE procedures were performed in 103 consecutive patients (age, 59 +/- 18 years; Simplified Acute Physiology Score, 46 +/- 14; body mass index, 26 +/- 9 kg/m2; positive end-expiratory pressure, 8 +/- 4 cmH2O). The number of acoustic windows was comparable using HHE and TTE (233/318 versus 238/318, P = 0.72). HHE had a lower overall diagnostic capacity than TTE (199/251 versus 223/251 clinical questions solved, P = 0.005), mainly due to its lack of spectral Doppler capability. In contrast, diagnostic capacity based on two-dimensional imaging was comparable for both approaches (129/155 versus 135/155 clinical questions solved, P = 0.4). In addition, HHE and TTE had a similar therapeutic impact in 45 and 47 patients, respectively (44% versus 46%, P = 0.9). CONCLUSIONS HHE appears to have a narrower diagnostic field when compared with conventional TTE, but promises to accurately identify diagnoses based on two-dimensional imaging in ventilated critically ill patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pharmacokinetics Alterations of Midazolam Infusion versus Bolus Administration in Mechanically Ventilated Critically Ill Patients

There is no randomized study carried out in order to compare their pharmacokinetic parameters although midazolam, as a sedative, has been widely administered via continuous infusion as well as intermittent bolus doses in mechanically ventilated critically ill patients. We prospectively investigated the effect of these two principal methods on pharmacokinetic parameters in 23 of mentioned patien...

متن کامل

Pharmacokinetics Alterations of Midazolam Infusion versus Bolus Administration in Mechanically Ventilated Critically Ill Patients

There is no randomized study carried out in order to compare their pharmacokinetic parameters although midazolam, as a sedative, has been widely administered via continuous infusion as well as intermittent bolus doses in mechanically ventilated critically ill patients. We prospectively investigated the effect of these two principal methods on pharmacokinetic parameters in 23 of mentioned patien...

متن کامل

Can Transthoracic Echocardiography Be Used to Predict Fluid Responsiveness in the Critically Ill Patient? A Systematic Review

Introduction. We systematically evaluated the use of transthoracic echocardiography in the assessment of dynamic markers of preload to predict fluid responsiveness in the critically ill adult patient. Methods. Studies in the critically ill using transthoracic echocardiography (TTE) to predict a response in stroke volume or cardiac output to a fluid load were selected. Selection was limited to E...

متن کامل

[The transoesophageal echocardiography in the general intensive care: its utility in the ventilated critically ill patient].

The use of the transoesophageal echocardiography (TEE) in the critically ill patient admitted to the general intensive care unit begins to turn out to be very important but it is still little spread. The full implementation of the echocardiography in the general intensive cares is compromised by the acoustic window. However, TEE can flyover this difficulty adding to the advantages widely descri...

متن کامل

Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient

BACKGROUND Cardiac output (CO) monitoring is a valuable tool for the diagnosis and management of critically ill patients. In the critical care setting, few studies have evaluated the level of agreement between CO estimated by transthoracic echocardiography (CO-TTE) and that measured by the reference method, pulmonary artery catheter (CO-PAC). The objective of the present study was to evaluate t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2003