Pulse Oximeter Oxygen Saturation in Prediction of Arterial Oxygen Saturation in Liver Transplant Candidates
نویسندگان
چکیده
BACKGROUND Liver transplant is the only definitive treatment for many patients with end stage liver disease. Presence and severity of preoperative pulmonary disease directly affect the rate of postoperative complications of the liver transplantation. Arterial blood gas (ABG) measurement, performed in many transplant centers, is considered as a traditional method to diagnose hypoxemia. Because ABG measurement is invasive and painful, pulse oximetry, a bedside, noninvasive and inexpensive technique, has been recommended as an alternative source for the ABG measurement. OBJECTIVES The aim of this study was to evaluate the efficacy of pulse oximetry as a screening tool in hypoxemia detection in liver transplant candidates and to compare the results with ABGs. PATIENTS AND METHODS Three hundred and ninety transplant candidates (237 males and 153 females) participated in this study. Arterial blood gas oxyhemoglobin saturation (SaO2) was recorded and compared with pulse oximetry oxyhemoglobin saturation (SpO2) results for each participants. The area under the curve (AUC) of receiver operating characteristic (ROC) curves was calculated by means of nonparametric methods to evaluate the efficacy of pulse oximetry to detect hypoxemia. RESULTS Roc-derived SpO2 threshold of ≤ 94% can predict hypoxemia (PaO2 < 60 mmHg) with a sensitivity of 100% and a specificity of 95%. Furthermore, there are associations between the ROC-derived SpO2 threshold of ≤ 97% and detection of hypoxemia (PaO2 < 70 mmHg) with a sensitivity of 100% and a specificity of 46%. The accuracy of pulse oximetry was not affected by the severity of liver disease in detection of hypoxemia. CONCLUSIONS Provided that SpO2 is equal to or greater than 94%, attained from pulse oximetry can be used as a reliable and accurate substitute for the ABG measurements to evaluate hypoxemia in patients with end stage liver disease.
منابع مشابه
Comparing the Effect of Simple Filtration Hemodialysis and Ultrafiltration Hemodialysis on Arterial Oxygen Saturation and Blood Pressure in Chronic Dialysis
Background and purpose: Hypoxemia and hypotension are important complications of hemodialysis in patients with chronic renal failure that are linked to several factors, including the type of filters used. The aim of this study was to compare the effect of simple filtration hemodialysis and ultrafiltration hemodialysis on blood pressure and blood arterial oxygen level. Materials and methods: In...
متن کاملNotes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.
Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As ...
متن کاملمقایسه اندازهگیری اشباع اکسیژن خون شریانی با پالس اکسیمتری و نمونه خون شریانی در بیماران بخش مراقبتهای ویژه قلبی
Background: Pulseoximetry is widely used in the critical care setting, currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SPO2 (puls-eoximetry oxygen saturation) in intensive care unit after cardiac surgery. Our objective was to compare pulseoximetry with arterial oxygen saturation (SaO2) during clinical routine in such patients, and to examine the eff...
متن کاملThe Effect of Controlled Breathing Exercises on Anxiety and Arterial Oxygen Saturation in Chronic Obstructive Pulmonary Disease
Introduction: Anxiety is one of the common symptoms and complications in patients with chronic obstructive pulmonary disease that increases readmission and decreases the quality of life in these patients. Objective: This study aimed to determine the effect of controlled breathing exercises on Anxiety and Arterial Oxygen Saturation in chronic obstructive pulmonary disease in the intensive care u...
متن کاملUsefulness of Pulse Oximeter That Can Measure SpO2 to One Digit After Decimal Point.
Pulse oximeters are used to noninvasively measure oxygen saturation in arterial blood (SaO2). Although arterial oxygen saturation measured by pulse oximeter (SpO2) is usually indicated in 1% increments, the value of SaO2 from arterial blood gas analysis is not an integer. We have developed a new pulse oximeter that can measure SpO2 to one digit after the decimal point. The values of SpO2 from t...
متن کامل