Change in Axial Length Pre and Post Cataract Surgery Measured with IOL Master
نویسندگان
چکیده
Objective: Cataract surgery with intraocular lens (IOL) implantation tries to get a refractive result nearby to the optic emmetropia. So an accurate IOL power calculation is mandatory, and axial length (AL) measurement is one of the most influential parameter in this calculation. IOL Master is one of the most popular devices to measure AL, which uses the same group refractive index of the lens for all patients, independently of the cataract grade. But lens refractive index is higher as cataract grade increases. Nowadays cataract tends to be operated earlier, so moderate cataracts are the most extracted in clinical practice. Therefore, it is important to study the influence of moderate lens opacity in AL measurements. The objective of this study was to compare the AL value measures with IOL Master, before and after uncomplicated cataract surgery in patients with moderate cataracts. Material and methods: This study included 153 eyes of 105 patients (67.51 ± 13.56 years old) undergoing uncomplicated cataract surgery. Lens opacity was determined with the LOCSIII scale and AL was measured using optical biometry (IOL Master; Carl Zeiss Meditec) before and one month after intervention. Intraoperative measurements (ultrasound time and fluid volume) were also registered. Results: Mean preoperative AL of 25.10 ± 3.19 mm (range 20.54 to 36.06; IC95% 24.59 to 25.60 mm) and postoperative of 24.88 ± 3.16 mm (IC 95% 24.37 to 25.39; range 20.43 to 35.79 mm). The mean AL difference before and after surgery was 0.19 ± 0.05 mm (p=0.549 ANOVA) with agreement limits from 0.09 to 0.29 mm. It was observed more difference in eyes with larger AL (r2=0.14 p<0.01). The average cataract grade in each category was: nuclear opacity 2.25 ± 1.00 (range 1 to 5) (p=0.564 ANCOVA), cortical opacity 2.04 ± 0.73 (range 0 to 4) (p=0.543 ANCOVA), posterior subcapsular opacity 0.44 ± 0.90 (range 0 to 4) (p=0.563 ANCOVA), and nuclear color 2.40 ± 1.05 (range 0 to 5) (p=0.558 ANCOVA), without statistical significant effect in the AL difference pre and after cataract surgery. The ultrasound time used during the surgery was 43 ± 29 seconds (p=0.525 ANCOVA) and the fluid volume was 4.73 ± 1.31 (p=0.560 ANCOVA) cubic centimeters without statistically significant relationship between these parameters and the difference in the AL measurement. Conclusions: The difference in AL measurement with IOL Master before and after cataract surgery in eyes with low grade of cataract should be related with IOL Master reproducibility especially in extreme-long eyes. Moderate cataract showed non-statistically effect on AL measurement with IOL Master biometry.
منابع مشابه
Comparison of the biometric measurements calculated with Zeiss IOL-Master and WaveLight OB-820
BACKGROUND The primary objective of this study was to investigate the level of agreement between IOL-Master and OB-820 ocular biometers. MATERIALS AND METHODS In this prospective randomized case series, we measured the anterior chamber depth (ACD), the axial length (AL), the corneal radii (R1, R2), the ratio of mean corneal radius and spherical equivalent and the corneal astigmatism (cylinder...
متن کاملInvestigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification
Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...
متن کاملAccuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study.
PURPOSE Partial Coherence Interferometry (PCI) is a fast, noncontact method to calculate lens implant power for cataract surgery. It has been reported as a potentially more accurate method than ultrasound biometry. Prospective study of the refractive outcomes of a consecutive series of patients undergoing phacoemulsification surgery with preoperative biometry by both ultrasound A-scan and PCI. ...
متن کاملMastering the IOLMaster 16
WHILE the IOLMaster has become an indispensable tool for pre-operative assessment of cataract patients, it is important to understand its limitations, reported British researchers at the 8th ESCRS Winter Refractive Surgery meeting. “Accurate and precise biometry is one of the key factors in obtaining a good refractive outcome after cataract surgery.An error of only 1.0 mm in axial length will r...
متن کاملVisual Outcomes and Refractive Status after Combined Silicone Oil Removal/Cataract Surgery with Intraocular Lens Implantation
Purpose To evaluate refractive status and identify predictors of surgical success following a combined silicone oil removal/cataract surgery with intraocular lens (IOL) implantation procedure. Methods In this single-armed, retrospective study, we reviewed patients who underwent vitreoretinal surgery followed by a combined silicone oil removal/cataract surgery procedure between 2009 and 2013. ...
متن کامل