Broadband diffuse optical spectroscopy measurement of hemoglobin concentration during hypovolemia in rabbits.

نویسندگان

  • Jangwoen Lee
  • D J Saltzman
  • A E Cerussi
  • D V Gelfand
  • J Milliken
  • T Waddington
  • B J Tromberg
  • M Brenner
چکیده

Serial blood draws for the assessment of trauma patients' hemoglobin (sHgb) and hematocrit (sHct) is standard practice. A device that would allow for continuous real-time, non-invasive monitoring of hemoglobin and tissue perfusion would potentially improve recognition, monitoring and resuscitation of blood loss. We developed a device utilizing diffuse optical spectroscopy (DOS) technology that simultaneously measures tissue scattering and near-infrared (NIR) absorption to obtain non-invasive measurements of oxy- (Hb-O(2)), deoxyhemoglobin (Hb-R) concentrations and tissue hemoglobin concentration (THC) in an animal model of hypovolemic shock induced by successive blood withdrawals. Intubated New Zealand White rabbits (N = 16) were hemorrhaged via a femoral arterial line every 20 min until a 20% blood loss (10-15 cc kg(-1)) was achieved to attain hypovolemia. A broadband DOS probe placed on the inner thigh was used to measure muscle concentrations of Hb-O(2) and Hb-R, during blood withdrawal. THC and tissue hemoglobin saturation (S(T)O(2)) were calculated from DOS [Hb-O(2)] and [Hb-R]. Broadband DOS-measured values were compared against traditional invasive measurements: systemic sHgb, arterial oxygen saturation (S(a)O(2)) and venous oxygen saturation (S(v)O(2)) drawn from arterial and central venous blood. DOS and traditional invasive measurements versus blood loss were closely correlated (r(2) = 0.96) showing a decline with removal of blood. S(T)O(2) and [Hb-O(2)] followed similar trends with hemorrhage, while [Hb-R] remained relatively constant. These measurements may be limited to some extent by the inability to distinguish between hemoglobin and myoglobin contributions to DOS signals in tissue at this time. Broadband DOS provides a potential platform for reliable non-invasive measurements of tissue oxygenated and deoxygenated hemoglobin and may accurately reflect the degree of systemic hypovolemia and compromised tissue perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive optical cytochrome c oxidase redox state measurements using diffuse optical spectroscopy.

A major need exists for methods to assess organ oxidative metabolic states in vivo. By contrasting the responses to cyanide (CN) poisoning versus hemorrhage in animal models, we demonstrate that diffuse optical spectroscopy (DOS) can detect cytochrome c oxidase (CcO) redox states. Intermittent decreases in inspired O2 from 100% to 21% were applied before, during, and after CN poisoning, hemorrh...

متن کامل

Non-Invasive Hemoglobin Monitoring during Hemorrhage and Hypovolemic Shock

Background: Serial blood draws for the assessment of a trauma patient’s hemoglobin (sHgb) and hematocrit (sHct) is standard practice. In the event of multiple casualties this process can be time consuming and lead to the inefficient use of valuable resources. A device that would allow for continuous real-time, non-invasive monitoring of hemoglobin and tissue perfusion would not only improve the...

متن کامل

Noninvasive in vivo monitoring of methemoglobin formation and reduction with broadband diffuse optical spectroscopy.

We present noninvasive, quantitative in vivo measurements of methemoglobin formation and reduction in a rabbit model using broadband diffuse optical spectroscopy (DOS). Broadband DOS combines multifrequency frequency-domain photon migration (FDPM) with time-independent near infrared (NIR) spectroscopy to quantitatively measure bulk tissue absorption and scattering spectra between 600 nm and 1,0...

متن کامل

Noninvasive in vivo monitoring of cyanide toxicity and treatment using diffuse optical spectroscopy in a rabbit model.

Currently, no reliable noninvasive methods exist for monitoring the severity of in vivo cyanide (CN) toxicity, treatment, and resulting physiological changes. We developed a broadband diffuse optical spectroscopy (DOS) system to measure bulk tissue absorption and scattering. DOS was used to optically monitor CN toxicity and treatment with sodium nitrite (NaNO2). To perform experiments, the DOS ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 27 8  شماره 

صفحات  -