Solving chemical problems of environmental importance using cavity ring-down spectroscopy.

نویسنده

  • Dean B Atkinson
چکیده

Cavity ring-down (CRD) is a sensitive variant of traditional absorption spectroscopy that has found increasing use in a number of chemical measurement applications. This review focuses on applications of cavity ring-down spectroscopy that will be of interest to environmental chemists and analytical chemists working on environmental problems. The applications are classified into direct monitoring approaches, indirect analysis methods and ancillary studies and a differentiation is made between field-tested instruments and proof of principle studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemical Sensing Using Fiber Cavity Ring-Down Spectroscopy

Waveguide-based cavity ring-down spectroscopy (CRD) can be used for quantitative measurements of chemical concentrations in small amounts of liquid, in gases or in films. The change in ring-down time can be correlated to analyte concentration when using fiber optic sensing elements that change their attenuation in dependence of either sample absorption or refractive index. Two types of fiber ca...

متن کامل

Evanescent Wave Cavity Ring-down Spectroscopy: a Future Technology for Process Sensing

Evanescent wave cavity ring-down spectroscopy (EW-CRDS) is described. The total internal reflection (TIR)-ring and monolithic folded cavity designs are briefly discussed. The performance of EW-CRDS for trace water vapor detection is evaluated by accounting for surface chemical and physical properties as well as intrinsic resonator properties. INTRODUCTION Cavity ring-down spectroscopy (CRDS) us...

متن کامل

The superposition principle and cavity ring-down spectroscopy

Cavity ring-down is becoming a widely used technique in gas phase spectroscopy. It holds promise for further important extensions, which will lead to even more frequent use. However, we have found widespread confusion in the literature about the nature of coherence effects, especially when the optical cavity constituting the ring-down cell is excited with a short coherence length laser source. ...

متن کامل

Applications of cavity ring-down spectroscopy to high precision isotope ratio measurement of 13C/12C in carbon dioxide.

Recent measurements of carbon isotopes in carbon dioxide using near-infrared, diode-laser-based cavity ring-down spectroscopy (CRDS) are presented. The CRDS system achieved good precision, often better than 0.2 per thousand, for 4% CO2 concentrations, and also achieved 0.15-0.25 per thousand precision in a 78 min measurement time with cryotrap-based pre-concentration of ambient CO2 concentratio...

متن کامل

Derivation of new equations for phase-shift cavity ring-down spectroscopy.

Current phase-shift cavity ring-down spectroscopy (PS-CRDS) experiments make use of equations originally developed for fluorescence studies. As these equations fail to take the length of the optical cavity and the superposition of reflecting beams into account, they lose validity as the length of the cavity increases. A new set of equations, based solely on the principles of PS-CRDS, is develop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 128 2  شماره 

صفحات  -

تاریخ انتشار 2003