An improved method for the delivery of artificial tears using an infusion pump.
نویسندگان
چکیده
Patients with markedly decreased or absent tear duct production require the frequent instillation of artificial tear preparations. Through animal experiments, a new method has been developed for the continuous infusion of these solutions. In this procedure, the canalicular system is intubated with fenestrated silastic tubing, which is subcutaneously tunnelled and then attached to a miniaturized and computerized pumping device. This makes it possible for a predetermined volume of solution to be automatically and continuously delivered. Using this technique, artificial tear solution was instilled at a rate of 1.75 microliter/min, a rate approximately the normal basic tear secretion rate (0.5-2.2 microliters/min). This resulted in a 14% increase in tear flow from preoperative values. This represents a 74% increase in tear secretion rates for patients with keratoconjunctivitis sicca. None of the experimental animals developed subcutaneous infections, dacryocystitis, or corneal ulcers. By utilizing the normal anatomy of the lacrimal drainage system, this new technique: does not compromise the conjunctival cul-de-sac or the salivary system, avoids the inconvenience of previous external devices, and allows for the automatic instillation of predetermined volumes of artificial tear solutions.
منابع مشابه
An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملAn Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملDevelopment of an Improved Fuzzy Approach to Model Potential Sites for Groundwater Artificial Recharge
Delineation of potential sites for groundwater artificial recharge is an important and challenging task. The purpose of this research is to develop a new data-driven fuzzy approach to model potential sites for groundwater artificial recharge. To achieve this end, the efficient criteria of a proper site for groundwater artificial recharge were first recognized and presented as a conceptual model...
متن کاملEffect of Foley Catheter in Prepration of Cervix for Delivery
Abstract The aim of this study was comparing the efficacy of induction of labor using balloon Foley catheter with conventional Oxytocin infusion method in cases of unfavorable cervix. 60 pregnant women that had an indication for induction of labor with a singleton vertex fetuses, intact membranes, and bishop score lower than 4 interred in this study and allocated in one of two induction method...
متن کاملIn-Vitro Red Blood Cells Integrity and Morphology Changes after Passing Through Volumetric Peristaltic Infusion Pump
Background: It is not clear whether the use of volumetric peristaltic infusion pumps, affect the quality of the erythrocytes during packed cell transfusion or not. In the present study in vitro quality of red blood cells was assessed after using this type of infusion pumps in a prospective study. Materials and Methods: In this study 60 units of packed red cells were examined before and after p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 27 8 شماره
صفحات -
تاریخ انتشار 1986