No improvement in long-term wear and revision rates with the second-generation Biomet cup (RingLoc) in young patients
نویسندگان
چکیده
BACKGROUND A number of excellent results with the cementless titanium femoral component of the Mallory Head Total Hip Replacement have been published. Unfortunately, these excellent results have been counteracted by the poor performance of the cementless titanium acetabular components. In 1994, the HexLoc acetabular component was replaced with a second-generation design, the RingLoc. We hypothesized that the new generation would have improved the results. METHODS We retrospectively studied 111 consecutive patients (150 hips) younger than 55 years. Median follow-up time was 14 (6-18) years for the HexLoc and 10 (1-14) years for the RingLoc. 7 patients were lost to follow-up and 7 patients died. The 10-year survival rate, radiographic liner wear, and radiographic signs of prosthesis failure were compared between the 2 acetabular components. RESULTS The Kaplan-Meier survival estimate with revision for any reason as the endpoint showed a 10-year survival of 89% (95% CI: 81-97) for the HexLoc and 92% (CI: 85-98) for the RingLoc. The mean annual wear rate for the HexLoc was 0.16 (SD 0.16) mm and it was 0.15 (0.1) mm for the RingLoc (p = 0.3). The radiographic signs of failure were equally distributed between the 2 groups. INTERPRETATION Compared to the HexLoc type, the RingLoc system did not improve the mean percentage survival at 10 years; nor did it reduce the liner wear. Despite correction of the known design flaws in the HexLoc design, the RingLoc system did not show a clinically relevant improvement compared to its predecessor.
منابع مشابه
Early Clinical Outcomes with a 3-D Porous Titanium Acetabular Cup
Cementless acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. 3-dimentional (3-D) porous coating and enhanced shell to a liner fixation are expected to reduce the polyethylene wear and to increase the longevity of an acetabular cup. The authors report the early clinical outcome with a cementless acetabular cup, Regenerex Ringloc+ (Zi...
متن کاملThe Ringloc liner compared with the Hexloc liner in total hip arthroplasty
The aim of this study was to compare the 10-year survival rate, pelvic osteolysis frequency and linear head penetration rate of the Hexloc and Ringloc liners used together with a partially threaded porous and hydroxyapatite coated cup and the Bi-Metric uncemented femoral stem. The 15-year results for the cup with the Hexloc liner are also reported. We included 332 consecutive hips (166 Hexloc a...
متن کاملLong Term Outcomes of Total Hip Arthroplasty in Young Patients under 30
Background: We aimed to report outcomes of total hip arthroplasty (THA) in very young patients under the year of 30. Methods: Thirty patients (45 hips) with various indications for THA were retrospectively reviewed radiologically and clinically and analyzed regarding survival, reasons of failure, factors associated with outcomes and postoperative complications. Results: Within a mean fol...
متن کاملMid- to long-term outcome of cementless total hip arthroplasty in younger patients.
PURPOSE To assess mid- to long-term outcomes of cementless primary total hip arthroplasty (THA) in younger patients. METHODS Records of 28 women and 34 men (75 hips) aged 18 to 55 (mean, 38) years who underwent primary THA using a hydroxyapatite-coated stem and a threaded cup and had been followed up for a mean of 10 (6-15) years were reviewed. 13 of the patients had bilateral THAs. Clinical ...
متن کاملRevision Fixation of Distal Humerus Fracture Nonunions in Older Age Patients with Poor Bone Quality or Bone Loss – Is This Viable as a Long-term Treatment Option?
Background: The purpose of this retrospective study was to analyze the long-term results of revision ORIF, jointcontracture release, and autogenous bone-grafting in the treatment of distal humerus frac-ture nonunions in older agedpatients with poor bone quality or bone loss who would have been candidates for total elbow arthroplasty.Methods: Seven patients (average age at inde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 82 شماره
صفحات -
تاریخ انتشار 2011