Linear phase-error correction for improved water and fat separation in dual-echo dixon techniques.

نویسندگان

  • Jingfei Ma
  • Zachary Slavens
  • Wei Sun
  • Ersin Bayram
  • Lloyd Estowski
  • Ken-Pin Hwang
  • James Akao
  • Anthony T Vu
چکیده

Large and spatially-linear phase errors along the frequency-encode direction may be induced by several common and hard-to-avoid system imperfections such as eddy currents. For data acquired in dual-echo Dixon techniques, the linear phase error can be more aggravated when compared to that acquired in a single echo and can pose challenges to a phase-correction algorithm necessary for successful Dixon processing. In this work, we propose a two-step process that first corrects the linear component of the phase errors with a modified Ahn-Cho algorithm (Ahn CB and Cho ZH, IEEE Trans. Med. Imaging 6:32, 1987) and then corrects the residual phase errors with a previously-developed region-growing algorithm (Ma J, Magn. Res. Med. 52:415, 2004). We demonstrate that successive application of the two-step process to data from a dual-echo Dixon technique provides a "1-2 punch" to the overall phase errors and can overcome local water and fat separation failures that are observed when the region-growing-based algorithm is applied alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-point Dixon imaging with flexible echo times and a region growing-based postprocessing algorithm

Introduction: The scan time for a two-point Dixon technique using dual-echo acquisition can become comparable with that for a conventional non-Dixon technique with similar scan parameters (1, 2). Recently, Xiang and Eggers et al. showed that images with echo times that are more flexible than being in-phase and out-of-phase can be used for two-point Dixon processing (3, 4). This increased flexib...

متن کامل

Water-fat separation with parallel imaging based on BLADE.

Uniform suppression of fat signal is desired in clinical applications. Based on phase differences introduced by different chemical shift frequencies, Dixon method and its variations are used as alternatives of fat saturation methods, which are sensitive to B0 inhomogeneities. Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) separates water and fa...

متن کامل

A Reliable, Efficient and Flexible multi-echo FSE based Water-Fat Separation Method

saturation scans. (c) and (d): 2D phase correction leads to superior water-fat separation than 1D linear phase correction (arrows). (d) also shows the chemical shift induced ringing at water-fat interface when the opposite polarity data are not combined (dashed arrows) Figure 2: Calculated NSA for the flexible echo shift strategy, where last echo is fixed at 7π/6, while ΔTE is determined by the...

متن کامل

Autocalibrating Correction of Spatially Variant Eddy Currents for Three-Point Dixon Imaging

Introduction Three-point Dixon methods assume in the separation linearity between the common phase of water and fat and the echo time [1]. The contributions to the common phase from field inhomogeneity adhere to linearity. In acquisitions that employ bipolar readout gradients to increase scan efficiency and decrease echo spacing, however, the common phase also includes contributions from eddy c...

متن کامل

Fast three-point Dixon MR imaging of the retrobulbar space with low-resolution images for phase correction: comparison with fast spin-echo inversion recovery imaging.

A new phase-correction algorithm for three-point Dixon (3PD) MR imaging allows on-line image reconstruction of three images per section: pure water, pure fat, and water plus fat. When combined with fast spin-echo acquisition, the sequence is suitable for routine MR imaging of the retrobulbar space. The 3PD pure water images have double the image signal-to-noise ratio of fast spin-echo inversion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 60 5  شماره 

صفحات  -

تاریخ انتشار 2008