Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography.
نویسندگان
چکیده
Heart rate variability (HRV) is traditionally derived from RR interval time series of electrocardiography (ECG). Photoplethysmography (PPG) also reflects the cardiac rhythm since the mechanical activity of the heart is coupled to its electrical activity. Thus, theoretically, PPG can be used for determining the interval between successive heartbeats and heart rate variability. However, the PPG wave lags behind the ECG signal by the time required for transmission of pulse wave. In this study, finger-tip PPG and standard lead II ECG were recorded for five minutes from 10 healthy subjects at rest. The results showed a high correlation (median = 0.97) between the ECG-derived RR intervals and PPG-derived peak-to-peak (PP) intervals. PP variability was accurate (0.1 ms) as compared to RR variability. The time domain, frequency domain and Poincaré plot HRV parameters computed using RR interval method and PP interval method showed no significant differences (p < 0.05). The error analysis also showed insignificant differences between the HRV indices obtained by the two methods. Bland-Altman analysis showed high degree of agreement between the two methods for all the parameters of HRV. Thus, HRV can also be reliably estimated from the PPG based PP interval method.
منابع مشابه
A preliminary attempt to understand compatibility of photoplethysmographic pulse rate variability with electrocardiogramic heart rate variability
In this study, we investigated the difference between heart rate variability (HRV) derived from electrocardiogramic(ECG) signals and pulse rate variability (PRV) derived from photoplethysmographic(PPG) signals. Fourteen healthy subjects conducted the protocol: 10 min physiological signals including distal pulse wave on finger and ear from photoplethysmography (PPG), and heart beat from electroc...
متن کاملHeart Rate Variability and the Acceleration Plethysmogram signals measured at rest
It is well-known that the electrocardiogram (ECG) is a non-invasive method that can be used to measure heart rate variability (HRV). Photoplethysmogram (PPG) signals also reflect the cardiac rhythm since the mechanical activity of the heart is coupled to its electrical activity. Photoplethysmography is a non-invasive, safe, and easy-to-use technique that has been developed for experimental use ...
متن کاملBlood Pressure and Heart Rate Variabilities Estimation Using Ballistocardiography
In this work a blood pressure and heart rate variability estimation system is presented. Instead of merely using beat-to-beat time interval extracted from the electrocardiogram (ECG), it is also used finger photoplethysmography (PPG) and ballistocardiography (BCG) information to have three independent estimates of the heart rate variability. Since pulse arrival and transit times can be extracte...
متن کاملComparison between Electrocardiographic and Earlobe Pulse Photoplethysmographic Detection for Evaluating Heart Rate Variability in Healthy Subjects in Short- and Long-Term Recordings
Heart rate variability (HRV) is commonly used to assess autonomic functions and responses to environmental stimuli. It is usually derived from electrocardiographic signals; however, in the last few years, photoplethysmography has been successfully used to evaluate beat-to-beat time intervals and to assess changes in the human heart rate under several conditions. The present work describes a sim...
متن کاملDynamic Metrics of Heart Rate Variability
Metrics of heart rate variability (HRV) are widely used in medical diagnostics, physiological research, and biofeedback training (TaskForce, 1996; Wheat & Larkin, 2010). HRV metrics are typically based on non-invasive measurements of cardiac function using electrocardiography (ECG) or photoplethysmography (PPG). A specific point is identified in each cardiac cycle, and the inter-beat interval (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical engineering & technology
دوره 32 6 شماره
صفحات -
تاریخ انتشار 2008