Use of sodium polyanetholesulfonate-CaCl2 for removal of serum nonspecific inhibitors of rubella hemagglutination: comparison with other polyanion-divalent cation combinations.

نویسندگان

  • M L Ellins
  • J B Campbell
چکیده

By using trypsin-treated human type O cells as indicators, we compared the abilities of four polyanion-divalent cation combinations (heparin-MnCl(2); high-and low-molecular-weight dextran sulfate-CaCl(2); and sodium polyanetholesulfonate [SPS]-CaCl(2)) for removal of serum non-immunoglobulin (lipoprotein) inhibitors of rubella hemagglutination. The combination of SPS-CaCl(2) was found to be the most effective, precipitating completely the pre-beta and beta-lipoproteins and reducing the alpha-lipoprotein levels by more than 50%. Hemagglutination patterns after this treatment were clear and stable, and, when normal sera were tested, hemagglutination-inhibition (HI) titers were comparable to those obtained after standard heparin-MnCl(2) treatment. High-molecular-weight dextran sulfate-CaCl(2) removed serum lipoproteins almost as effectively as SPS-CaCl(2). However, problems of nonspecific agglutination and the heavy hemagglutination patterns resulting made this combination unacceptable for routine purposes. Neither low-molecular-weight dextran sulfate-CaCl(2) nor heparin-MnCl(2) removed the pre-beta lipoproteins completely, and occasionally traces of beta-lipoprotein also remained after treatment. The presence of pre-beta lipoproteins in normal sera after treatment may be of no consequence in the HI test since we have found that the very-low-density lipoprotein fractions obtained by ultracentrifugal methods from normal sera (those corresponding to the pre-beta fractions obtained by electrophoresis) had no HI activity. However, very-low-density lipoprotein fractions from all hyperlipemic sera tested had HI activity (titers ranging from 1:16 to 1:1,024) which, in the majority of cases, was not eliminated after heparin-MnCl(2) treatment. In every case, treatment with SPS-CaCl(2) removed this nonspecific activity completely. Since hyperlipemic sera may occasionally be encountered in routine rubella HI antibody testing, we recommend the use of SPS-CaCl(2) rather than heparin-MnCl(2) for pretreatment of sera.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rubella hemagglutination inhibition: removal of nonspecific agglutination due to manganous chloride.

Nonspecific inhibitors of rubella hemagglutination can be removed by treatment of sera with heparin-manganous chloride for use in the hemagglutination-inhibition test. After removal of nonspecific inhibitors by this procedure, an excess of manganous chloride may remain. This may cause the cells to agglutinate, thus obscuring the reading at low serum dilutions. This disadvantage can be overcome ...

متن کامل

Simple procedure for the removal of nonspecific inhibitors of rubella virus hemagglutination.

The adsorption of serum lipoproteins onto an insoluble matrix of colloidal silicic acid results in the removal of nonspecific inhibitors of rubella virus hemagglutinin. The procedure can be performed in 15 min at room temperature. Comparative studies using both the dextran sulfate-CaCl2 and heparin-MnCl2 methods for removal of inhibitors demonstrated that the colloidal silicic acid procedure yi...

متن کامل

Improved amplification of microbial DNA from blood cultures by removal of the PCR inhibitor sodium polyanetholesulfonate.

Molecular methods are increasingly used to identify microbes in clinical samples. A common technical problem with PCR is failed amplification due to the presence of PCR inhibitors. Initial attempts at amplification of the bacterial 16S rRNA gene from inoculated blood culture media failed for this reason. The inhibitor persisted, despite numerous attempts to purify the DNA, and was identified as...

متن کامل

Solid-phase radioimmunoassay of rubella virus immunoglobulin M antibodies: comparison with sucrose density gradient centrifugation test.

The solid-phase radioimmunoassay (RIA) method developed in our laboratory for demonstrating rubella virus-specific immunoglobulin G (IgG) antibodies (Kalimo et al., 1976) was further developed for demonstrating IgM antibodies. A total of 188 serum specimens were tested. The statistical probability of obtaining a false-positive IgM result, based on determinations of 100 rubella-negative sera, wa...

متن کامل

Improved rubella hemagglutination inhibtion test: inactivation of non-immunoglobulin hemagglutination inhibitors by phospholipase C.

A method using phospholipase C (PL-C) for removing nonspecific inhibitors (NSI) of rubella virus hemagglutinin is described. PL-C was found to hydrolyze NSI without altering the hemagglutination inhibition (HI) activity of the specific antibody and could be used to remove NSI in the rubella HI test by using formalinized erythrocytes, which resisted the enzymatic action; fresh erythrocytes were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 1977