Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
نویسندگان
چکیده
Today, the majority of coronary stents are balloon-expandable and are deployed using a balloon-tipped catheter. To improve deliverability, the membrane of the angioplasty balloon is typically folded about the catheter in a pleated configuration. As such, the deployment of the angioplasty balloon is governed by the material properties of the balloon membrane, its folded configuration and its attachment to the catheter. Despite this observation, however, an optimum strategy for modelling the configuration of the angioplasty balloon in finite element studies of coronary stent deployment has not been identified, and idealised models of the angioplasty balloon are commonly employed in the literature. These idealised models often neglect complex geometrical features, such as the folded configuration of the balloon membrane and its attachment to the catheter, which may have a significant influence on the deployment of a stent. In this study, three increasingly sophisticated models of a typical semi-compliant angioplasty balloon were employed to determine the influence of angioplasty balloon configuration on the deployment of a stent. The results of this study indicate that angioplasty balloon configuration has a significant influence on both the transient behaviour of the stent and its impact on the mechanical environment of the coronary artery.
منابع مشابه
Balloon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury.
Endovascular stents expand the arterial lumen more than balloon angioplasty and reduce rates of restenosis after coronary angioplasty in selected patients. Understanding the factors involved in vascular injury imposed during stent deployment may allow optimization of stent design and stent-placement protocols so as to limit vascular injury and perhaps reduce restenosis. Addressing the hypothesi...
متن کاملStent deployment resolves a petrous carotid artery angioplasty dissection.
A patient with a symptomatic petrous carotid artery stenosis underwent balloon angioplasty, which was complicated by a flow-limiting dissection. The problem was resolved by deploying a balloon-expandable coronary stent. The patient suffered no neurologic deficit, was discharged within 12 hours, and was asymptomatic at last follow-up, 5 months after the procedure, without warfarin therapy. This ...
متن کاملNumerical investigations of the structural behavior of a balloon expandable stent design using finite element method
This paper discusses some issues regarding the structural behavior of a Balloon-Expandable (BE) stent made of stainless steel material (AISI316L). BE stent is a tubular, often mesh-like, structure which is expanded inside a diseased (stenosed) artery segment to restore blood flow and keep the vessel open following angioplasty. Most of BE stent designs have two fundamental constituents: expandab...
متن کاملAn Adolescent Patient with Coarctation of Aorta Treated with Self-Expandable Nitinol Stent
Transcatheter treatment of aortic coarctation, with balloon angioplasty or stent implantation, is now an acceptable alternative to surgical repair. However these procedures may result in complications, such as vascular wall injury and re-stenosis of the lesion. A nitinol self-expandable stent, when deployed at the coarctation site, produces low constant radial force, which may result in a gradu...
متن کاملStent dislodgement in left anterior descending coronary artery and successful deployment with two parallel wires and a small balloon.
Coronary artery stent dislodgement during angioplasty is a rare complication. Stent dislodgement was more frequent in the past when stents were manually crimped onto the balloon. Newer and improved balloon-mounted stents with better radio-opacity have reduced the incidence of stent dislodgement but do not completely eliminate it. We report a case of balloon-mounted stent dislodgement in the pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal for numerical methods in biomedical engineering
دوره 29 11 شماره
صفحات -
تاریخ انتشار 2013