Synoptic Approach of Synchronous Generator on Disconnection Processes in Electric Power Systems Comprising Generator Circuit Breakers

نویسندگان

  • CORNELIA A. BULUCEA
  • MARC A. ROSEN
  • DORU A. NICOLA
  • NIKOS E. MASTORAKIS
  • CARMEN A. BULUCEA
چکیده

This paper is a sequel to a study by the authors of electric power systems comprising the generator circuit-breakers (GCBs) at power plant generator terminals. A sustainable assessment of the current interruption requirements of a GCB addresses the main stresses on the generator circuit breaker, revealing that the GCB current interruption requirements are significantly higher than for the distribution network circuit breakers. Hence, generator circuit-breakers are subject to unique demanding conditions caused by specific stresses, namely: high asymmetrical fault currents resulting from high d.c. components of the fault current; greater electrical, thermal and mechanical stresses when interrupting longer arcing time faults; and important dielectric stress after the electric arc extinction caused by the transient recovery voltage (TRV). This paper extends other studies of the authors on the energetic and exergetic transformation chain at the interruption current transient process in an electric power system that comprises the generator circuit-breaker, as well as the transient recovery voltage which appears after the interruption of a short-circuit fed by the synchronous generator or by the main step-up transformer. For achieving the TRV equivalent configuration the authors applied the method of operational symmetrical components (o.s.c.), and utilized the operational impedances of the synchronous generator and of the main transformer, depending on the fault location. Modeling the transient recovery voltage of circuits emphasizes aspects with direct implications on commutation equipment. Thus, the o.s.c. method can be applied at the poles of any breaker, for any eliminated fault type, if the network configuration and elements are known. The TRV, which appears after the interruption of a short-circuit fed by the generator, may be considered like an oscillation, where the oscillation factor and the rising rate (RR) of the TRV are established by the electrical machine parameters: resistance, inductance and capacitance. Consequently, modeling of concentrated equivalent parameters of the synchronous generator at perturbations caused by current interruption transient processes is achieved in this study through an approach based on sustainability concepts. These findings allow for simulations of the transient recovery voltage and comparisons with experimental results. Key-Words: electric arc; generator circuit-breaker; sustainability, synchronous generator; transient recovery voltage

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Approaching the Processes in the Generator Circuit Breaker at Disconnection through Sustainability Concepts

Nowadays, the electric connection circuits of power plants (based on fossil fuels as well as renewable sources) entail generator circuit-breakers (GCBs) at the generator terminals, since the presence of that electric equipment offers many advantages related to the sustainability of a power plant. In an alternating current (a.c.) circuit the interruption of a short circuit is performed by the ci...

متن کامل

تخمین پارامترهای مدل کلاسیک ژنراتور با استفاده از داده های PMU

Parameters estimation of dynamic model of synchronous generators is an essential prerequisite for viable and reliable power system operation and offline studies. Advent of phasor measurement units (PMU) and its growing applications in power systems have led to an evolution in the electric power network wide-area monitoring, protection, and control. Alongside, these devices have revealed unprece...

متن کامل

Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

The doubly fed induction generator (DFIG) is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE) event is among the most frequent failures in electric generators. However, LOE detection stud...

متن کامل

Application to Adaptive Control to Synchronous Machine Excitation

Self-tuning adaptive control technique has the advantage of being able to track the system operating conditions so that satisfactory control action can always be produced. Self-tuning algorithms can be implemented easily. Because the power systems are usually time varying non-linear systems and their parameters vary, adaptive controllers are very suitable for power systems. Characteristics of a...

متن کامل

Reliability Based Optimal Preventive Maintenance Policy for High Voltage Circuit Breakers in Power Plants

  Electric power industry have always try to provide reliable electricity to customers and at the same time decrease system costs. High Voltage circuit-breakers are an essential part of the power network. This study has developed a maintenance and replacement scheduling model for high voltage circuit- breakers that minimize maintenance costs while maintaining the acceptable reliability. This mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014