Analysis of the Geometrical and Physical Fluctuations While Performing Intrinsic Uniformity Test for Philips Forte Gamma Camera
نویسنده
چکیده
Intrinsic flood field uniformity is a fundamental quality control test that is considered as prerequisite for performing clinical routine exams using the gamma camera. Every gamma camera vendor provides recommended geometrical and physical parameters that should be followed while performing this test. Conventional methods using NEMA recommended parameters also can be used as well. The aim of the current study was to analyze the geometrical and physical fluctuations during performing intrinsic uniformity test for the gamma camera. Materials and Methods: The intrinsic uniformity was tested for one detector of Philips Forte dual head gamma camera while changing the following geometrical factors the source distance from the detector face, the point source volume and the off-center in the X axis for the source position. Other physical factors were tested; the numbers of acquired counts and the matrix size used in the acquisition protocol, all tests have been done for both integral and differential intrinsic uniformity. The Tc 99m radioactive source was used for performing the tests and it measured using a calibrated dose calibrator. Results showed that the best intrinsic uniformity was found at 200 cm point source to detector face distance, the source position from the center of the detector face in the xaxis should be at the center ( zero shift), the total number of acquired counts during the test should be from 30-60 M count and gives the best results at 30 M counts, the point source volume should be from 0.1 to 0.5 ml and the matrix size used in the acquisition protocol should be adjusted with 512X512 matrix. Conclusion: There were statistically significant differences between the results for each studied factor which indicates that there is an optimum value that should be used in each test at which the best integral and differential uniformity results were measured, deviation from this value lead to deterioration of the integral and differential uniformity as well, which in turn will affect the clinical image. Also there are acceptable limits by which the results of the test could be accepted for each factor studied according to the NEMA specifications of the studied (Philips, Forte) gamma camera.
منابع مشابه
New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کاملThe Impact of Daily Flood Uniformity Test on Quality of Images: A Case Report
The Daily intrinsic flood uniformity test of a gamma camera is required to be performed before using the gamma camera to acquire patient images. It is meant to detect changes in the performance of a gamma camera system that may affect the interpretation of clinical studies adversely. Citation: Ejeh JE, Adedapo KS (2012) The Impact of Daily Flood Uniformity Test on Quality of Images: A Case Repo...
متن کاملIntrinsic uniformity and relative sensitivity quality control tests for single-head gamma cameras.
OBJECTIVE We sought to determine the best parameters for rapid performance of daily quality control testing of intrinsic uniformity and relative sensitivity for the single-head gamma-camera system in our nuclear medicine department. METHODS The effects of the following parameters on intrinsic uniformity were studied: gamma source activity, number of acquired counts for the flood image, source...
متن کاملComparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes
Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...
متن کاملEvaluation of different physical parameters that affect the clinical image quality for gamma camera by using different radionuclides
Some scintillation camera manufactures adhere to standard code of performance specification established by National Electric Manufactures Association (NEMA). Items such as differential and integral uniformity, spatial resolution energy resolution, etc. are all calculated with reproducible methodology that allows the user reliable technique for creation of these standards to avoid any lack of cl...
متن کامل