eComment: the Six Sigma approach: from mobile phones to chest tubes.

نویسندگان

  • Luca Bertolaccini
  • Alberto Terzi
چکیده

of increased length of hospitalization on a general thoracic surgery service: a prospective observational study. (Copenhagen, Denmark): Were there any patients in either of the groups where you had to reinsert a tube due to subcutaneous emphysema or pneumothorax after tube removal? Dr. Pompili: No. In this series we had no cases with pneumothorax or other complications after removal of the chest drain. (Copenhagen, Denmark): That's great. I think it is an interesting option, and you are now giving a fixed rate for when the tube can be removed, but is it still the doctor's single decision or is it actually so fixed and so secure that you would even allow the OR medical staff to make the decision on when the tube can be removed? Dr. Pompili: This is a good point, because in this case, unlike a surgical procedure where you have to learn a technical skill, the learning curve is more like a confidence curve. The staff have to have confidence in the safety of the criteria for removing the chest tube. Chest tube removal criteria were decided a priori based on the consensus opinion of major centers with experience in using these digital devices. We think that it is safe to remove a chest tube when the airflow is >40 ml/min. It should be even safer with Thopaz since it shows the graph of airflow in the last 24 h, allowing the detection of higher spikes of air leak. (Copenhagen, Denmark): But it is still the surgeon who looks at the graph and who does the decision-making? Dr. Pompili: The medical staff are in charge of making this decision in our setting. Dr. J. Kuzdzal (Krakow, Poland): You said that there was a difference in the overall cost of treatment in favor of the Thopaz device. Did you also include in this calculation the price of the Thopaz unit itself, which is quite considerable? Dr. Pompili: The calculation is based on the entire hospital stay costs. We found no differences between the costs of the devices. Thopaz is a reuse-able pump, and the cost of consumables for one patient is the same as with traditional devices. Therefore, our cost differences are due mainly to the differences in hospital stay influenced by the duration of chest tube usage. Dr. J. Kuzdzal (Krakow, Poland): But was the cost of the pump itself, which is very high, included in …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of mobile phone waves on salivary secretion in dental students of Rafsanjan University of Medical Sciences

Background: Excessive use of mobile phones is addictive and causes many complications. The severity of these complications depends on the duration of the call and the frequency of using mobile phones. Therefore, this study aimed to determine the effect of mobile phone waves on salivary secretion. Materials and Methods: This descriptive study was conducted on 120 dental students in Rafsanjan, Ir...

متن کامل

Evaluation of the Interference of the Microwave Radiation Emitted from GSM Mobile Phones on the Performance of Cell Counters

Abstract Background and Objectives: Incidents related to electromagnetic interference with medical devices have been reported over the past decades. It has also been indicated that the microwave radiation emitted from mobile phones interferes with the operation of medical devices therefore, this study aimed at testing the interference by GSM mobile phones with cell counters. Material and Method...

متن کامل

Study of Bacterial Contamination of Mobile Phones and Stethoscopes in Neonatal Intensive Care Unit

Mobile phones and stethoscopes used in neonatology units could be colonized by potentiel bacteria pathogens. It can be a vector of severe nosocomial infections and multi-drug-resistant pathogens. The aim of this study is to evaluate the microbial contamination of mobile phones and stethoscopes, used by medical and paramedical staff. The study was conducted in neonatal intensive care unit (NICU)...

متن کامل

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

The Pattern of Mobile Phone Use and Prevalence of Self-Reported Symptoms in Elementary and Junior High School Students in Shiraz, Iran

Background: The use of mobile phone by children is increasing drastically. Children are likely to accumulate many years of exposure during their lives. Furthermore, as nervous systems in children are developing, children may be at a greater risk compared to adults. In this light, some scientists have suggested that the use of mobile phones should be restricted in high-risk groups such as childr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 2011