Rf Accelerating System for a Compact Ion Synchrotron
نویسندگان
چکیده
We have developed an RF accelerating system for a compact ion synchrotron. The RF cavity is an untuned type loaded with FINEMET cores, which have high complex permeability, high saturation flux density, and high Curie temperature properties. A new power feeding method, “multi-feed coupling,” was developed to match the cavity impedance with output impedance of a solidstate RF amplifier. We have installed the RF accelerating system for a multi-purpose synchrotron at the Wakasawan Energy Research Centre in Japan. Ion beams were successfully accelerated by adjusting the RF control system using a direct digital synthesiser. For proton beam acceleration, dual-harmonics operation was effective to enhance the beam intensity due to reduction of the spacecharge effect.
منابع مشابه
Beam Commissioning of a Multi-purpose Compact Ion Synchrotron
W-MAST (Wakasa-wan Energy Research Center Multipurpose Accelerator with Synchrotron and Tandem) consists of a tandem accelerator with 5MV terminal voltage and a compact ion synchrotron. The beam commissioning was started at the beginning of 1999 and was successfully accomplished in March 2000. A proton beam of 10MeV was injected from the tandem accelerator and accelerated by the ion synchrotron...
متن کاملIon Production with a High-power Short-pulse Laser for Application to Cancer Therapy
Ion production process with a high-power (~50TW) short-pulse (20fs) laser is to be utilized as a compact injector of the synchrotron for cancer therapy. In the scheme, an RF voltage with the frequency of 160 MHz is applied to the laser produced ion-beam within the energy space to reduce the momentum spread to ±1%, which is further cooled down to ±0.1 % by an electron beam cooling to realize nee...
متن کاملAn Automatic Real Time Impedance Matching System for Use in an RF Electrostatics Accelerator Ion Source
متن کامل
A Possible Upgrade for the Srs Rf System
The worlds first dedicated source for synchrotron radiation, the Synchrotron Radiation Source (SRS) at Daresbury, UK is now 20 years old. During its operational lifetime, the control and stability of the electron and photon beams have been significantly improved, to ensure continued reliable operation, in order to necessitate various lattice and insertion device (ID) upgrades [1][2]. The SRS c...
متن کاملStudy of the Synchrotron and Betatron Oscillations for the Siam Photon Source
The storage ring in the Siam Photon Source of National Synchrotron Research Center, THAILAND is the upgraded version of SORTEC storage ring. The magnet lattice structure is changed to obtain the low emittance and to include the long straight sections to provide space for the insertion devices. Therefore, a detailed analysis of the modified parameters of the synchrotron and betatron oscillations...
متن کامل