Effectiveness of Doppler Image of the Vertebral Artery as an Anatomical Landmark for Identification of Ultrasound-Guided Target Level in Cervical Spine

نویسندگان

  • Dong-Hyuk Choi
  • Heun-Guyn Jung
  • Jeong-Ho Lee
  • Ji-Hoon Park
  • Yong-Soo Choi
چکیده

STUDY DESIGN A prospective sonographic study. PURPOSE To verify the effectiveness of simultaneous application of two landmarks, Doppler image of the vertebral artery and shape of the transverse tubercle of the seventh cervical (C7) vertebra. OVERVIEW OF LITERATURE Counting upwards from the C7 vertebra which only has a posterior tubercle of the transverse process is a commonly used method for ultrasound-guided cervical nerve root block. However, each transverse process has a different shape. METHODS Sonograms of 20 volunteers were examined. At first, we identified the C7 transverse process based on the presence of the vertebral artery without the anterior tubercle. The C5 and C6 transverse processes were identified based on the presence of anterior tubercle without the vertebral artery. Subsequently, we placed needles on the C5, C6, and C7 transverse processes and the location and direction of needles were confirmed by fluoroscopy. RESULTS In the 120 segments, 93.3% of needles were placed correctly as desired; 97.5% of needles were placed on the 5C transverse process; 97.5% of needles were placed on the C6 transverse process; and 85.0% of needles were placed on the C7 transverse process, respectively. Both sides showed the same accuracy of 93.3%. CONCLUSIONS Simultaneous application of Doppler image of the vertebral artery and shape of the C7 transverse tubercle showed 93.3% accuracy in identifying the target cervical level. Therefore, Doppler image of the vertebral artery can be considered to be a useful landmark for ultrasound-guided cervical nerve root block.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of Ultrasound-guided and Anatomic landmark-based Superficial Cervical Plexus Block on Post-operative Pain Intensity in Thyroidectomy Patients: A Clinical Trial

Background and Objective: Pain is one of the most common complications after thyroidectomy. Opioid administration can overcome this complication, however, it has some side effects, including nausea and vomiting. So, the use of local anesthetic instead of opioids is a good alternative. This study was conducted to evaluate and compare the effect of ultrasound-guided superficial cervical plexus bl...

متن کامل

EVALUATION OF THE RESULTS OF SURGICAL AND MEDICAL TREATMENT IN 16 PATIENTS WITH VERTIGO SECONDARY TO CERVICAL SPONDYLOSIS

 ABSTRACT Background: In patients with cervical spondylosis, cord compression and impingement of cord vessels as well as the vertebral artery may be accompanied by vertigo. We evaluated improvement of vertigo in these patients after surgical and medical treatment. Methods: In this prospective study we reviewed 16 patients with vertigo suspected of cervical spondylosis, admitted to our hospital ...

متن کامل

The Validation of Ultrasound-Guided Target Segment Identification in Thoracic Spine as Confirmed by Fluoroscopy

Background The role of ultrasound in the thoracic spine has been underappreciated, partly because of the relative efficacy of the landmark-guided technique and the limitation of imaging through the narrow acoustic windows produced by the bony framework of thoracic spine. The aim of this study was to make a comparison between the 12th rib and the spinous process of C7 as a landmark for effective...

متن کامل

Rare Variation in the Right Vertebral Artery

The variations of vertebral artery are important with regard to their potential clinical impact .The study reports the variation of course of right vertebral artery in male cadaver. The vertebral arteries arise from the superioposterior aspect of the first part of subclavian artery. The vessel takes a vertical course to enter into the transverse foramen of sixth cervical vertebra. Right vertebr...

متن کامل

Ultrasonographic examination of the normal caprine neonatal brain

Ultrasonography is a safe, rapid, and non-invasive diagnostic tool that has been previously used for imaging infants and canine neonatal brains. The purpose of the present study was to describe the ultrasonographic appearance of the brain in clinically normal caprine neonates. Ultrasonographic examination was done on 12 day-old goat kids, transverse and sagittal transcranial scans were obtained...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015