Acoustic Characterization of Prosthetic Heart Val Yes
نویسندگان
چکیده
Prosthetic heart valves are a blessing for people with defective heart valves. One type of mechanical heart valve that was manufactured between 1979 and 1985 has been implanted in approximately 86,000 people. Between 500 and 600 of these valves are known to have failed. The failure occurs when a thin wire strut breaks free, see Figure l. The strut has two legs that are attached to the main body of the heart valve. Typically one of the legs breaks first, leaving the other leg intact and the heart valve still functioning. This condition is called a single leg separation. A technique that analyzes the sound generated by the heart valve was developed to detect this single leg separation. Acoustic data was acquired from implanted heart valves prior to their being explanted. These signals were processed and distinguishing characteristics have been identified that correlated the condition of the heart valve strut with its acoustic signature. An automated classification algorithm was developed and trained to predict the heart valve's condition.
منابع مشابه
Pregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves
There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...
متن کاملAn Electromagnetic Acoustic Technique for Non-invasive Defect Detection in Mechanical Prosthetic Heart Valves
An Electromagnetic Acoustic based Technique (EMAT) has been shown to be successful in detecting strut failures in mechanical prosthetic heart valves. [1] The technique works on the basis of the differences between the acoustic resonant modes displayed by intact and fractured valve struts. The defect detection problem is complicated by the fact that the signal from the heart valve is mixed with ...
متن کاملPreparation and Characterization of Aluminum Nitride Thin Films with the Potential Application in Electro-Acoustic Devices
In this work, aluminum nitride (AlN) thin films with different thicknesses were deposited on quartz and silicon substrates using single ion beam sputtering technique. The physical and chemical properties of prepared films were investigated by different characterization technique. X-ray diffraction (XRD) spectra revealed that all of the deposited films have an amorphous str...
متن کاملOn the Use of Acoustic Emission and Digital Image Correlation for Welded Joints Damage Characterization
A series of tests have been conducted to investigate fatigue damage characterization in corroded welded steel plates using structural health monitoring (SHM) techniques. Acoustic Emission (AE) is a non-destructive testing (NDT) technique with potential applications for locating and monitoring fatigue cracks in service. In the present work, AE is implemented to characterize damage during crack e...
متن کاملA rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure
Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011