A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies
نویسندگان
چکیده
The widely used Logan plot in radioligand receptor dynamic PET studies produces marked noise-induced negative biases in the estimates of total distribution volume (DV(T)) and binding potential (BP). To avoid the inconsistencies in the estimates from the Logan plot, a new graphical analysis method was proposed and characterized in this study. The new plot with plasma input and with reference tissue input was first derived to estimate DV(T) and BP. A condition was provided to ensure that the estimate from the new plot equals DV(T) or BP. It was demonstrated theoretically that 1) the statistical expectations of the estimates from the new plot with given input are independent of the noise of the target tissue concentration measured by PET; and 2) the estimates from the time activity curves of regions of interest are identical to those from the parametric images for the new plot. The theoretical results of the new plot were also confirmed by computer simulations and fifty-five human [(11)C]raclopride dynamic PET studies. By contrast, the marked noise-induced underestimation in the DV(T) and BP images and noise-induced negative bias in the estimates from the Logan plot were demonstrated by the same data sets used for the new plot. The computational time for generating DV(T) or BP images in the human studies was reduced by 80% on average by the new plot in contrast to the Logan plot. In conclusion, the new plot is a consistent and computationally efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies.
منابع مشابه
Multi-graphical analysis of dynamic PET
In quantitative dynamic PET studies, graphical analysis methods including the Gjedde-Patlak plot, the Logan plot, and the relative equilibrium-based graphical plot (RE plot) (Zhou Y., Ye W., Brasić J.R., Crabb A.H., Hilton J., Wong D.F. 2009b. A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studi...
متن کاملOptimum Conditions of Radioligand Receptor Binding Assay of Ligands of Benzodiazepine Receptors
To obtain drugs which are more selective at benzodiazepine (BZD) receptors, design and synthesis of functionally selective ligands for BZD receptors is the current strategy of our pharmaceutical chemistry department. The affinity of newly synthesized ligands is assessed by radioligand receptor binding assays. Based on our previous studies, 2-phenyl-5-oxo-7-methyl-1,3,4-oxadiazolo[a,2,3]-pyrimid...
متن کاملOptimum Conditions of Radioligand Receptor Binding Assay of Ligands of Benzodiazepine Receptors
To obtain drugs which are more selective at benzodiazepine (BZD) receptors, design and synthesis of functionally selective ligands for BZD receptors is the current strategy of our pharmaceutical chemistry department. The affinity of newly synthesized ligands is assessed by radioligand receptor binding assays. Based on our previous studies, 2-phenyl-5-oxo-7-methyl-1,3,4-oxadiazolo[a,2,3]-pyrimid...
متن کاملOptimized production and quality control of 68Ga-DOTATATE
Introduction: Optimized production and quality control of 68Ga-DOTATATE as an efficient and preferable PET radiotracer for somatostatin receptor imaging in neuroendocrine tumors is of great interest. In this study effort has been made to present a fast, efficient, cost-effective and facile protocol for 68Ga-DOTATATE productions for clinical trials. Methods:68Ga...
متن کاملImproved quantification of salivary gland scintigraphy by means of factor analysis
Introduction: In this study the automatic separation of oral and salivary gland activity and spontaneous secretion by means of factor analysis for quantitative salivary gland scintigraphy is introduced. Methods: After intravenous administration of 99mTc sodium pertechnetate, dynamic scintigraphy was performed. 20 minutes after tracer application 2 ml of lemon juice was delivered to stimulate t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2009