Basic Investigation The Genesis Stent: A New Low-Profile Stent for Use in Infants, Children, and Adults With Congenital Heart Disease
نویسندگان
چکیده
Placement of intravascular stents that can reach adult size in infants and smaller children has been limited by the large profile and poor flexibility of currently available stents. In vitro and in vivo testing of the Genesis stent was performed to evaluate crimpability, predeployment flexibility, and radial strength. Comparisons were made to the Palmaz iliac and IntraStent (IS) LD stents. Nine physicians placed 30 Genesis stents in swine pulmonary and systemic arteries to evaluate stent deliverability/crimpability. Two swine were recovered and underwent a second catheterization 8 weeks later, where the stents (n 8) were reexpanded to maximal size. Angiographic and intravascular ultrasound (IVUS) assessments were performed. In vitro testing revealed the Genesis stent to have superior crimpability, flexibility, and comparable radial strength to the Palmaz iliac stent, and superior crimpability and radial strength and comparable flexibility to the IS LD series. During in vivo testing, the physicians graded the Genesis stent superior to the Palmaz stent regarding crimpability and deliverability, and superior to the IS LD stent in regard to crimpability, and comparable to or superior in deliverability. In the chronic animals, the Genesis stent was expanded up to maximal diameter 8 weeks following implantation. Angiographic and IVUS revealed no fractures no in-stent restenosis. The Genesis stent can be easily delivered through smaller sheaths, which will facilitate their use in infants and smaller children with vascular stenosis. Cathet Cardiovasc Intervent 2003;59:406–414. © 2003 Wiley-Liss, Inc.
منابع مشابه
Closed External End Double J Catheter as a Nephrostent in Pyeloplasty for Infants with Uretero-Pelvic Junction Obstruction
Uretero-Pelvic Junction Obstruction (UPJO) is a common congenital anomaly that may need pyeloplasty to prevent renal function deterioration. The purpose of this study was to describe a modified use of jj stent catheter in pyeloplasty for infant with UPJO. A series of 12 children, between 3 and 10 months, underwent stenting open pyeloplasty. In each patient a 6 French Foley catheter was placed w...
متن کاملPrognostic Value of Soluble ST2 (sST2) Serum Levels in Infants and Children with Heart Failure Complicating Congenital Heart Disease
Background Heart failure (HF) in infants and children with congenital heart disease (CHD) is a crucial complication with different outcomes. Many biomarkers are used as prognostic indicators. Soluble ST2 (sST2) is one of these markers studied in adults with HF. We aimed to study the prognostic value of sST2 in CHD children with HF. Materials and Methods In current case-control study, thirty-six...
متن کاملMaterials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent
Transcatheter treatment of children with congenital heart disease such as coarctation of the aorta and pulmonary artery stenosis currently involves the use of metal stents. While these provide good short term results, there are long term complications with their use. Children outgrow metal stents, obligating them to future transcatheter dilations and eventual surgical removal. A bioabsorbable s...
متن کاملEvaluating the overt extracardiac malformations in children with congenital heart disease in Khuzestan Province
Background: Extracardiac malformations can be seen in 20-45% of infants with congenital heart disease (CHD). Chromosomal abnormalities exist in 5-10% of patients with CHD. The aim of this study was to assess the frequency of overt extra cardiac malformations in children with CHD. Methods: This descriptive epidemiologic study was conducted on 720 patients with CHD referred to the pediatric ca...
متن کاملEvaluation of Brain Natriuretic Peptide, Tumor Necrosis Factor and Interleukin-6 Plasma Levels in Infants and Children with Congenital Heart Disease
Background Congenital heart disease (CHD) is the most common cause of major congenital birth defect. The aim of this study was to investigate the association of CHD with serum levels of Tumor necrosis factor-α (TNFα), Interleukin 6 (IL-6), and B-type Natriuretic Peptide (BNP) in infant and children. Materials and Methods The present study was conducted in Heshmat heart hospital and 17 Shahrivar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -