Continuous quality control of the blood sampling procedure using a structured observation scheme

نویسندگان

  • Tine Lindberg Seemann
  • Mads Nybo
چکیده

INTRODUCTION An observational study was conducted using a structured observation scheme to assess compliance with the local phlebotomy guideline, to identify necessary focus items, and to investigate whether adherence to the phlebotomy guideline improved. MATERIALS AND METHODS The questionnaire from the EFLM Working Group for the Preanalytical Phase was adapted to local procedures. A pilot study of three months duration was conducted. Based on this, corrective actions were implemented and a follow-up study was conducted. All phlebotomists at the Department of Clinical Biochemistry and Pharmacology were observed. Three blood collections by each phlebotomist were observed at each session conducted at the phlebotomy ward and the hospital wards, respectively. Error frequencies were calculated for the phlebotomy ward and the hospital wards and for the two study phases. RESULTS A total of 126 blood drawings by 39 phlebotomists were observed in the pilot study, while 84 blood drawings by 34 phlebotomists were observed in the follow-up study. In the pilot study, the three major error items were hand hygiene (42% error), mixing of samples (22%), and order of draw (21%). Minor significant differences were found between the two settings. After focus on the major aspects, the follow-up study showed significant improvement for all three items at both settings (P < 0.01, P < 0.01, and P = 0.01, respectively). CONCLUSION Continuous quality control of the phlebotomy procedure revealed a number of items not conducted in compliance with the local phlebotomy guideline. It supported significant improvements in the adherence to the recommended phlebotomy procedures and facilitated documentation of the phlebotomy quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peykan check, a simple continuous quality control method for hematology analyzers

A simple inexpensive con!nuous quality control method, by means of eight basic blood coun!ng parameters, obtained from automated hematology analyzers, using pa!ent samples, is described. A few samples with low, normal and high values were selected and introduced to the instrument early in the morning as the first count, the results of which are plo#ed on the appropriate chart as dots. The sa...

متن کامل

Bias and Unbias Comparison between Economic Statistical Design T2-VSI and T2-FRS Control Charts

The Hotelling's  control chart, is the most widely used multivariate procedure for monitoring  two or more related quality characteristics, but it’s power lacks the desired performance in detecting small to moderate shifts. Recently, the variable sampling intervals (VSI) control scheme in which the length of successive sampling intervals is determined upon the preceding values has been proved t...

متن کامل

Costs and Benefits of Beef Cattle Fattening Schemes in some Selected Areas of North West Tanzania

This study highlights the costs and benefits of indigenous beef cattle fattening schemes in Shinyanga Urban and Kishapu Districts in Tanzania. Specifically, in this study the net profit (NP) for fatteners between beef cattle fattening schemes has been determined. The schemes were divided into two main categories, scheme 1 in which the animals were fed on cottonseed hulls (CSHL) based diets and ...

متن کامل

Economic Statistical Design of a Three-Level Control Chart with VSI Scheme

Traditionally, the statistical quality control techniques utilize either an attributes or variables product quality measure. Recently, some methods such as three-level control chart have been developed for monitoring multi attribute processes. Control chart usually has three design parameters: the sample size (n), the sampling interval (h) and the control limit coefficient (k).The design parame...

متن کامل

ADAPTIVE FUZZY TRACKING CONTROL FOR A CLASS OF PERTURBED NONLINEARLY PARAMETERIZED SYSTEMS USING MINIMAL LEARNING PARAMETERS ALGORITHM

In this paper, an adaptive fuzzy tracking control approach is proposed for a class of single-inputsingle-output (SISO) nonlinear systems in which the unknown continuous functions may be nonlinearlyparameterized. During the controller design procedure, the fuzzy logic systems (FLS) in Mamdani type are applied to approximate the unknown continuous functions, and then, based on the minimal learnin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2016