Bioelectric impedance measurement for fluid status assessment.

نویسنده

  • Antonio Piccoli
چکیده

BACKGROUND Adequacy of body fluid volume improves short- and long-term outcomes inpatients with heart and kidney disorders. Bioelectrical impedance vector analysis (BIVA) has the potential to be used as a routine method at the bedside for assessment and management of body fluids. METHODS Impedance (Z vector) is a combination of resistance, R (function of intra- and extracellular fluid volume) and reactance, Xc (function of the dielectric material of tissue cells), with the best signal to noise ratio at 50 kHz. BIVA allows a direct assessment of body fluid volume through patterns of vector distribution on the R-Xc plane without the knowledge of the body weight. Reference tolerance ellipses (50, 75 and 95%) for the individual vector were previously calculated in the healthy population. RESULTS We determined the optimal vector distribution in patients undergoing hemodialysis without hypotension or intradialytic symptoms. Most vectors lay within the reference 75% tolerance ellipse of the healthy population indicating full electrical restoration of tissues. We also determined the optimal vector distribution of patients undergoing continuous ambulatory peritoneal dialysis without edema and with a residual urine output. The vector distribution was close to the distribution of both healthy subjects and pre-session distribution of hemodialysis patients. We established the relationship between central venous pressure and BIVA in critically ill patients. Shorter vectors (overhydration) were associated with increasing venous pressure, whereas longer vectors were associated with decreasing venous pressure. The association between BIVA and NT-proBNP has been evaluated in patients with acute cardiac-related dyspnea. In the 'gray zone' of NT-proBNP values between 'ruling out' and 'ruling in' acute heart failure, BIVA detected latent peripheral congestion. CONCLUSION Simple patterns of BIVA allow detection, monitoring, and control of hydration status using vector displacement for the feedback on treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does bioimpedance analysis or measurement of natriuretic peptides aid volume assessment in peritoneal dialysis patients?

Cardiovascular mortality remains the commonest cause of death for peritoneal dialysis patients. As such, preventing persistent hypervolemia is important. On the other hand, hypovolemia may potentially risk episodes of acute kidney injury and loss of residual renal function, a major determinant of peritoneal dialysis technique survival. Bioimpedance has developed from a single-frequency research...

متن کامل

Use of Bioelectrical Impedance Analysis for the Assessment of Nutritional Status in Critically Ill Patients

Malnutrition is common in the critically ill patients and known to cause a variety of negative clinical outcomes. However, various conventional methods for nutrition assessment have several limitations. We hypothesized that body composition data, as measured using bioelectrical impedance analysis (BIA), may have a significant role in evaluating nutritional status and predicting clinical outcome...

متن کامل

Bioelectrical impedance spectroscopy for the assessment of body fluid volumes of term neonates.

The assessment of fluid volume in neonates by a noninvasive, inexpensive, and fast method can contribute significantly to increase the quality of neonatal care. The objective of the present study was to calibrate an acquisition system and software to estimate the bioelectrical impedance parameters obtained by a method of bioelectrical impedance spectroscopy based on step response and to develop...

متن کامل

The role of bioelectrical impedance analysis, NT-ProBNP and inferior vena cava sonography in the assessment of body fluid volume in children with nephrotic syndrome.

BACKGROUND Assessment of volume status and differentiating "underfill" and "overfill" edema is essential in the management of patients with nephrotic syndrome (NS). OBJECTIVES Our aim was to evaluate the volume status of NS patients by using different methods and to investigate the utility of bioelectrical impedance analysis (BIA) in children with NS. METHODS The hydration status of 19 pati...

متن کامل

Practical Aspects of Volume Control in Chronic Kidney Disease Using Whole Body Bioimpedance

Background: Fluid status is an independent predictor of mortality in dialysis patients. Current methods of fluid assessment have several limitations. Summary: An ideal method should be cheap, portable, easy to perform without extensive training, reproducible and determines patients’ excess or deficit of total body water. Bioimpedance analysis (BIA) fulfils many of these criteria and can give ad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contributions to nephrology

دوره 164  شماره 

صفحات  -

تاریخ انتشار 2010