Optimizing bag-valve-mask ventilation with a new mouth-to-bag resuscitator.
نویسندگان
چکیده
When ventilating an unintubated patient with a self-inflating bag, high peak inspiratory flow rates may result in high peak airway pressure with subsequent stomach inflation; this may occur frequently when rescuers without daily experience in bag-valve-mask ventilation need to perform advanced airway management. The purpose of this study was to assess the effects of a newly developed self-inflating bag (mouth-to-bag resuscitator; Ambu, Glostrup, Denmark) that limits peak inspiratory flow. A bench model simulating a patient with an unintubated airway was used, consisting of a face mask, manikin head, training lung (lung compliance, 100 ml/0.098 kPa (100 ml/cm H(2)O)); airway resistance, 0.39 kPa/l per second (4 cm H(2)O/l/s), oesophagus (LESP, 1.96 kPa (20 cm H(2)O)) and simulated stomach. Twenty nurses were randomised to ventilate the manikin for 1 min (respiratory rate: 12 per minute) with either a standard self-inflating bag or the mouth-to-bag resuscitator, which requires the rescuer to blow up a single-use balloon inside the self-inflating bag, which in turns displaces air towards the patient. When supplemental oxygen is added, ventilation with up to 100% oxygen may be obtained, since expired air is only used as the driving gas. The mouth-to-bag resuscitator therefore allows two instead of one hand sealing the mask on the patient's face. The volunteers were blinded to the experimental design of the model until completion of the experimental protocol. The mouth-to-bag resuscitator versus standard self-inflating bag resulted in significantly (P<0.05) higher mean+/-S.D. mask tidal volumes (1048+/-161 vs. 785+/-174 ml) and lung tidal volumes (911+/-148 vs. 678+/-157 ml), longer inspiratory times (1.7+/-0.4 vs. 1.4+/-0.4 s), but significantly lower peak inspiratory flow rates (50+/-9 vs. 62+/-13 l/min) and mask leakage (10+/-4 vs. 15+/-9%); peak inspiratory pressure (17+/-2 vs. 17+/-2 cm H(2)O) and stomach tidal volumes (16+/-30 vs. 18+/-35 ml) were comparable. In conclusion, employing the mouth-to-bag resuscitator during simulated ventilation of an unintubated patient in respiratory arrest significantly decreased inspiratory flow rate and improved lung tidal volumes, while decreasing mask leakage.
منابع مشابه
Effects of decreasing inspiratory flow rate during simulated basic life support ventilation of a cardiac arrest patient on lung and stomach tidal volumes.
If the airway of a cardiac arrest patient is unprotected, basic life support with low rather than high inspiratory flow rates may reduce stomach inflation. Further, if the inspiratory flow rate is fixed such as with a resuscitator performance may improve; especially when used by less experienced rescuers. The purpose of the present study was to assess the effect of limited flow ventilation on r...
متن کاملComparison of an oxygen-powered flow-limited resuscitator to manual ventilation with an adult 1,000-mL self-inflating bag.
BACKGROUND Positive-pressure ventilation of patients with unprotected airways during cardiopulmonary resuscitation can cause gastric dilation. OBJECTIVE Determine if there is a significant difference in volume delivered to lungs and stomach while using an adult 1,000-mL disposable bag-valve-mask (BVM) device and the oxygen-powered, flow-limited Oxylator EMX resuscitator. METHODS We used a b...
متن کاملCough Augmentation in Subjects With Duchenne Muscular Dystrophy: Comparison of Air Stacking via a Resuscitator Bag Versus Mechanical Ventilation.
BACKGROUND Air stacking improves cough effectiveness in people with Duchenne muscular dystrophy (DMD) and respiratory muscle weakness. However, it is not known whether air stacking is more effective via a resuscitator bag or a home ventilator. METHODS This prospective randomized study investigated the effect of air stacking via a volume-cycled home ventilator versus via a resuscitator bag in ...
متن کاملAn audible indication of exhalation increases delivered tidal volume during bag valve mask ventilation of a patient simulator.
Self-inflating manual resuscitators (SIMRs) can mislead caregivers because the bag, unlike a Mapleson-type device, reinflates even without patient exhalation. We added a whistle as an audible indicator to the exhalation port of a SIMR. In randomized order, each participant provided two sets of breaths via mask ventilation with a SIMR, one with and one without audible feedback, to a Human Patien...
متن کاملبررسی سهولت تهویه تنفسی با ماسک، با جاگذاری گاز تا شده در
Back ground & Aims: In the edentulous patients some authors suggest to leave dentures in when ventilating with bag-mask. In this research, we suggest a more efficient method. Materials & Methods: In the prospective blind randomized clinical trial we included 200 patients (age≥55) into two groups. After induction of anesthesia in all groups, in the group I, we placed folded gauze in each bucca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Resuscitation
دوره 56 2 شماره
صفحات -
تاریخ انتشار 2003