Variations in dosimetric distribution and plan complexity with collimator angles in hypofractionated volumetric arc radiotherapy for treating prostate cancer
نویسندگان
چکیده
PURPOSE Hypofractionated radiotherapy can reduce treatment durations and produce effects identical to those of conventionally fractionated radiotherapy for treating prostate cancer. Volumetric arc radiotherapy (VMAT) can decrease the treatment machine monitor units (MUs). Previous studies have shown that VMAT with multileaf collimator (MLC) rotation exhibits better target dose distribution. Thus, VMAT with MLC rotation warrants further investigation. METHODS AND MATERIALS Ten patients with prostate cancer were included in this study. The prostate gland and seminal vesicle received 68.75 and 55 Gy, respectively, in 25 fractions. A dual-arc VMAT plan with a collimator angle of 0° was generated and the same constraints were used to reoptimize VMAT plans with different collimator angles. The conformity index (CI), homogeneity index (HI), gradient index (GI), normalized dose contrast (NDC), MU, and modulation complexity score (MCSV ) of the target were analyzed. The dose-volume histogram of the adjacent organs was analyzed. A Wilcoxon signed-rank test was used to compare different collimator angles. RESULTS Optimum values of CI, HI, and MCSV were obtained with a collimator angle of 45°. The optimum values of GI, and NDC were observed with a collimator angle of 0°. In the rectum, the highest values of maximum dose and volume receiving 60 Gy (V60 Gy ) were obtained with a collimator angle of 0°, and the lowest value of mean dose (Dmean ) was obtained with a collimator angle of 45°. In the bladder, high values of Dmean were obtained with collimator angles of 75° and 90°. In the rectum and bladder, the values of V60 Gy obtained with the other tested angles were not significantly higher than those obtained with an angle of 0°. CONCLUSION This study found that MLC rotation affects VMAT plan complexity and dosimetric distribution. A collimator angle of 45° exhibited the optimal values of CI, HI, and MCSv among all the tested collimator angles. Late side effects of the rectum and bladder are associated with high-dose volumes by previous studies. MLC rotation did not have statistically significantly higher values of V60 Gy in the rectum and bladder than did the 0° angle. We thought a collimator angle of 45° was an optimal angle for the prostate VMAT treatment plan. The findings can serve as a guide for collimator angle selection in prostate hypofractionated VMAT planning.
منابع مشابه
Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملSU-E-T-604: Dosimetric Dependence On the Collimator Angle in Prostate Volumetric Modulated Arc Therapy.
PURPOSE The purpose of this study is to investigate the dose-volume variations of planning target volume (PTV) and organs-at-risk (OARs) in prostate volumetric modulated arc therapy (VMAT) when using different collimator angles. It is because collimator angle awareness is essential for planner to produce an optimal prostate VMAT plan in a rational time. METHODS Single-arc VMAT plans at differ...
متن کاملDosimetric Effect Resulting From the Collimator Angle, the Isocenter Move, and the Gantry Angle Errors
Introduction: Dose distribution can be affected by diverse parameters, such as beam orientations, and collimator angles. These parameters should respect and maintain the international recommended levels during the realization of the quality assurance protocols of linear accelerators. This study aimed at evaluating the dosimetric effects on treatment quality considering...
متن کاملValidation of the relative insensitivity of volumetric-modulated arc therapy (VMAT) plan quality to gantry space resolution
Volumetric-modulated arc therapy (VMAT) is an efficient form of radiotherapy used to deliver intensity-modulated radiotherapy beams. The aim of this study was to investigate the relative insensitivity of VMAT plan quality to gantry angle spacing (GS). Most previous VMAT planning and dosimetric work for GS resolution has been conducted for single arc VMAT. In this work, a quantitative comparison...
متن کاملThe effects of volumetric changes on radiation doses of the rectum and bladder during radiotherapy in patients with prostate cancer
Background: In prostate radiotherapy, changes in the volume of the bladder and rectum can influence dose delivery. In this study, cone-beam computerised tomography (CBCT) imaging was used to assess volumetric, and corresponding radiation dosimetric changes, for the bladder and rectum in patients with prostate cancer treated using VMAT. Materials and Methods: Treatment planning computed tomograp...
متن کامل