Clinical applications of the Mini-Screw-Anchorage-System (M.A.S.) in the maxillary alveolar bone.

نویسندگان

  • Aldo Carano
  • Stefano Velo
  • Cristina Incorvati
  • Paola Poggio
چکیده

AIMS anchorage control with self-tapping screws has become an important part of the clinical management of the orthodontic patients. Mechanical resistance and sites of insertion of miniscrews as orthodontic anchorage are critical to ensure successful outcomes. Aim of this clinical study was threefold: 1) to measure the mechanical resistance of the M.A.S., 2) to evaluate if the alveolar areas usually selected for mini-screws placement are adequate, 3) to illustrate the most frequent clinical application on the maxillary alveolar bone. METHODS two methods were chosen to test these screws mechanically, representing two potential modes of failure during insertion or removal: torsional strenght and bending strenght. Three-dimension images of fifty maxillas have been retrieved from a group of 200 patients, age range between 20 and 40 years with a new type of tomogram called Newtom System. For each area mesio-distal and labio-lingual measurements from four horizontal cuts made at 2-5-8-11 mm below the bone-crest have been evaluated. RESULTS the mean value of resistance to breakage in torsion is of 48.7 N.cm (around 5 Kg) for the miniscrew of 1.5 diameter, while the mean value of resistance to breakage in torsion is of 23.4 N.cm (around 2 Kg) for the miniscrew of 1.3 diameter.. The mean value of resistance to breakage in flexion is of 120.4 N (around 12 Kg) for the miniscrew of 1.5 diameter, while the mean value of resistance to the flexion is of 63.7 N (around 6 Kg) for the miniscrew of 1.3 diameter. On the maxillary alveolar bone the highest amount of bone was in mesio-distal dimension between 6 and 5 on the palatal side (minimum 1.9 mm at -11 mm cut; maximum 5.5 mm at -5 mm cut). The smallest amount of bone was in the tuber (minimum 0.2 mm; maximum 1.3 mm). Examination of the labio-palatal dimension demonstrated similar high thickness between 5-6 and 6-7 (minimum 3.7 mm at -11 mm cut; maximum 13.2 mm at -2 mm cut). The smallest amount of bone was recorded on the tuber (minimum 0.6 mm; maximum 4.1 mm). The following clinical applications are described: Closure of the extractions space, Symmetric intrusion of the incisors, Correction of the cant of the plane of occlusion and of the dental midline, Molar intrusion of one or two teeth, Molar distalization with the Distal Jet and miniscrews, Molar mesialization, Intermaxillary anchorage. CONCLUSIONS the mechanical resistance of the miniscrews M.A.S. is suitable for their use in orthodontics. The best anatomical zones for their implantation are the interradicular spaces mesial to the first maxillary molars. From our experience to date, the miniscrews are a reliable and convenient system for skeletal anchorage when compared with other more invasive osseo-integrated systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of palatally inserted mini-screw for upper molar distalization: A case series

 Abstract Reports have shown that molars can be distalized successfully with virtually no orthodontic anchorage loss with an intraosseous anchorage, even with fully erupted second molars. The purpose of this study was evaluating the effects of mini-screws as skeletal anchorage for upper molar distalization. In this case series, three patients needing maxillary first molar distalization,...

متن کامل

Bone-Borne Maxillary Expansion and Traditional Rapid Maxillary Expansion: A Systematic Review and Meta-Analysis

Introduction: The aim of this study was to perform a systematic review and meta-analysis to compare the effect of bone-borne expansion (BBE) and tooth-borne expansion (TBE) in patients with maxillary constriction. Methods: Electronic databases, including MEDLINE, EMBASE, and Cochrane Central Register of Controlled Trials, were searched up to February 2019. Elig...

متن کامل

Treatment of Skeletal Anterior Open Bite Using Absolute Anchorage: A Case Report and Review

 Background and purpose: Skeletal anchorage is a new aid for the correction of moderate anterior open bite. This study aimed at treating moderate anterior open bite using posterior intrusion via mini implants. In addition, a review of studies carried out on open bite correction using absolute anchorage was performed. Materials and methods: The following keywords were used: open bite, camouflag...

متن کامل

Treatment of a severely atrophic maxilla using an immediately loaded, implant-supported fixed prosthesis without the use of bone grafts: a clinical report.

This report describes a clinical approach to using the zygomatic and pterygomaxillary bones to provide additional anchorage for longer implants to support an immediately functional maxillary screw-retained provisional fixed prosthesis. The purpose is to report the problems of patients who have experienced the most severe form of maxillary alveolar resorption and to demonstrate a specific protoc...

متن کامل

Molar Uprighting Using Mini-Screws after Distalization by the Pendulum Appliance: A Case Report

A 16-year-old Class II female patient was treated without tooth extraction. The upper first molars were distalized by the Pendulum appliance. After six months, the molars tipped significantly to the distal. To correct this side effect, we decided to upright the molars using skeletal anchorage. On each side, a mini-screw was inserted between first and second premolars in the buccal cortical plat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Progress in orthodontics

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 2004