Evaluation of body weight as a predictive factor for transvenous ventricular defibrillation characteristics.
نویسندگان
چکیده
AIMS To investigate the correlation between body weight and defibrillation threshold (DFT) for transvenous lead systems using a porcine model. METHODS AND RESULTS Twenty-eight pigs were anaesthetised and DFTs assessed in single and dual coil configurations using a four-reversal binary search method. DFT was correlated with body weight in the RV --> Can and RV --> SVC + Can configurations. A Pearson correlation coefficient and a two-sided p-value were calculated. A positive correlation exists between body weight and DFT in RV --> Can (r=0.66, p<0.000) and RV --> SVC + Can (r=0.44, p=0.018). CONCLUSION There is a significant correlation between body weight and DFT in swine. This tends to be greater in the two-electrode than in the three-electrode configuration. With these and previous human observations, one may predict a higher DFT in heavy individuals and make appropriate procedural adjustments.
منابع مشابه
A simplified, single-lead unipolar transvenous cardioversion-defibrillation system.
BACKGROUND Transvenous implantable cardioverter-defibrillators provide significant advantages in the treatment of patients with life-threatening ventricular arrhythmias. However, present technology requires considerable electrophysiology expertise, multiple incisions, and long operative times for successful implementation. METHODS AND RESULTS In this study, we present a prototype of a new, ea...
متن کاملAtrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.
OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...
متن کاملTransvenous defibrillation in humans via the coronary sinus.
A consistently effective transvenous defibrillation system for use in automatic defibrillators could significantly alter the approach to patients at risk of sudden death. Transvenous defibrillation systems that use a right ventricular (RV) electrode only or an RV electrode in combination with a chest patch are relatively inefficient at applying current to the posterolateral left ventricle. An R...
متن کاملA permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation.
A transvenous lead system for implantable defibrillators would obviate a surgical thoracotomy and reduce the morbidity and mortality associated with implantation. We evaluated the clinical performance of a new nonthoracotomy lead system that included a defibrillation lead in the coronary sinus. At the time of defibrillator implantation, transvenous defibrillation leads were inserted percutaneou...
متن کاملAn Experimental Study of Transvenous Defibrillation Using a Coronary Sinus Catheter
KADISH, A.H., ET AL.: An Experimental Study of Transvenous Defibrillation Using a Coronary Sinus Catheter. The efficacy of a transvenous defibrillating system, utilizing bipolar right ventricular and coronary sinus catheters was evaluated in 14 normal mongrel'dogs. Tivo groups of seven animals each were studied^ During all shocks, the right ventricular apex electrode sensed as the anode. In bot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 6 1 شماره
صفحات -
تاریخ انتشار 2004