A finite element model of an idealized diarthrodial joint to investigate the effects of variation in the mechanical properties of the tissues.

نویسندگان

  • F H Dar
  • R M Aspden
چکیده

The stiffness of articular cartilage increases dramatically with increasing rate of loading, and it has been hypothesized that increasing the stiffness of the subchondral bone may result in damaging stresses being generated in the articular cartilage. Despite the interdependence of these tissues in a joint, little is understood of the effect of such changes in one tissue on stresses generated in another. To investigate this, a parametric finite element model of an idealized joint was developed. The model incorporated layers representing articular cartilage, calcified cartilage, the subchondral bone plate and cancellous bone. Taguchi factorial design techniques, employing a two-level full-factorial and a four-level fractional factorial design, were used to vary the material properties and thicknesses of the layers over the wide range of values found in the literature. The effects on the maximum values of von Mises stress in each of the tissues are reported here. The stiffness of the cartilage was the main factor that determined the stress in the articular cartilage. This, and the thickness of the cartilage, also had the largest effect on the stresses in all the other tissues with the exception of the subchondral bone plate, in which stresses were dominated by its own stiffness. The stiffness of the underlying subchondral bone had no effect on the stresses generated in the cartilage. This study shows how stresses in the various tissues are affected by changes in their mechanical properties and thicknesses. It also demonstrates the benefits of a structured, systematic approach to investigating parameter variation in finite element models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Crash Injury Analysis of Knee Joint Considering Pedestrian Safety

Background: Lower extremity injuries are frequently observed in car-to-pedestrian accidents and due to the bumper height of most cars, knee joint is one of the most damaged body parts in car-to-pedestrian collisions.Objective: The aim of this paper is first to provide an accurate Finite Element model of the knee joint and second to investigate lower limb impact biomechanics in car-to-pede...

متن کامل

Study of Stone-wales Defect on Elastic Properties of Single-layer Graphene Sheets by an Atomistic based Finite Element Model

In this paper, an atomistic based finite element model is developed to investigate the influence of topological defects on mechanical properties of graphene. The general in-plane stiffness matrix of the hexagonal network structure of graphene is found. Effective elastic modulus of a carbon ring is determined from the equivalence of molecular potential energy related to stretch and angular defor...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Investigating the Effects of Cold Bulge Forming Speed on Thickness Variation and Mechanical Properties of Aluminum Alloys: Experimental and Numerical

In this work, cold bulge forming of an Aluminium-Magnesium (Al-Mg) sheet with a solid bulging medium is performed experimentally and numerically.  Mechanical properties and thickness variations of Al-Mg sheet are evaluated before and after the forming process.  The results indicated that the Al-Mg sheet has taken the desired shape without necking using the cold bulge forming process.  Also, the...

متن کامل

An investigation of the effects of osteoporosis, impact intensity and orientation on human femur injuries: a parametric finite element study

Objective: Femur is the strongest, longest and heaviest bone in the human body. Due to the great importance of femur in human body, its injury may cause large numbers of disabilities and mortality. Considering various effective parameters such as mechanical properties, geometry, loading configuration, etc. can propel the study to the trustable results.. Methods: A 3D finite element model of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 217 5  شماره 

صفحات  -

تاریخ انتشار 2003