Small animal imaging using a conventional gamma camera exemplified in studies on the striatal dopaminergic system.

نویسندگان

  • Christoph Scherfler
  • Clemens Decristoforo
چکیده

BACKGROUND Small animal imaging has recently been the subject of increasing interest and specific imaging devices in particular for positron emission tomography (PET) have been developed. To bypass limitations arising from high acquisition costs and dependence on an in-house cyclotron unit inevitably associated with PET, a conventional gamma camera has been equipped with a pinhole collimator and used to visualize striatal pre- and post-synaptic dopaminergic function in rats measured by the dopamine transporter ligand [123I]beta-CIT and the dopamine D2/dopamine D3 receptor ligand [123I]IBZM. In order to precisely estimate brain regions of low radioligand uptake, single photon emission computed tomography (SPECT) images were coregistered onto an MRI template. MATERIAL AND METHODS Our pinhole SPECT/MRI approach has been employed in animal models of pre- and postsynaptic dopaminergic dysfunction. The physical characteristics of the scanner, the tracer kinetics and modelling as well as image postprocessing have been addressed and associated intrinsic problems and constraints discussed. CONCLUSIONS An outlook has been provided on the application of pinhole SPECT and MRI coregistration towards non-invasive investigations of drug-receptor interactions and binding characteristics of newly developed radiopharmaceuticals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Bremsstrahlung imaging from the liver using the Monte Carlo simulation

Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...

متن کامل

Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera

Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution.  The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...

متن کامل

Effect of Dexamethasone on Striatal Neurotransmissions in the Rats Subjected to Parkinson’s Disease Animal Model

Objective(s) The aim of this study was to evaluate the effects of dexamethasone on striatal dopaminergic, glutamatergic and gamma amino butyric acid (GABA) ergic neurotransmission in normal and parkinsonian rats. Materials and Methods Dexamethasone (0.15, 0.30, 0.60 and 0.8 mg/kg) was administered to normal or parkinsonian rats (i.p.) followed by the analysis of the striatal neurotransmitter...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nuclear medicine review. Central & Eastern Europe

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2006