Coupled Mach-Zehnder interferometer memory element.

نویسندگان

  • Martin T Hill
  • H J S Dorren
  • X J M Leijtens
  • J H den Besten
  • T de Vries
  • J H C van Zantvoort
  • E Smalbrugge
  • Y S Oei
  • J J M Binsma
  • G D Khoe
  • M K Smit
چکیده

Two active Mach-Zehnder interferometers are integrated in a monolithic InP/InGaAsP photonic integrated circuit. Together they form a crucial component for optical signal processing: an optical memory element or set-reset flip-flop. The switching time for this initial device is approximately 200 ps. The photonic integrated circuit contains active and passive optical components, including electro-optic phase shifters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Review of Optical Routers in Photonic Networks-on-Chip: A Literature Survey

Due to the increasing growth of processing cores in complex computational systems, all the connection converted bottleneck for all systems. With the protection of progressing and constructing complex photonic connection on chip, optical data transmission is the best choice for replacing with electrical interconnection for the reason of gathering connection with a high bandwidth and insertion lo...

متن کامل

-

In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...

متن کامل

Two Step on-axis Digital Holography Using Dual–channel Mach–Zehnder Interferometer and Matched Filter Algorithm

A new two step on-axis digital holography (DH) is proposed without any assumptions, phase shifting, or complicated optical components. A dual-channel Mach-Zehnder interferometer was employed. Using that setup, the object field can be reconstructed requiring only two step measurements. To eliminate position difference between two charge-coupled device (CCD) cameras, a matched filter algorithm wa...

متن کامل

Polymeric Mach-Zehnder interferometer using serially coupled microring resonators.

We propose a novel geometry for a Mach-Zehnder interferometer in which one arm of the interferometer consists of serially coupled microresonators and the other a simple ridge waveguide. The device was fabricated in an optical polymer and its spectral characteristics were measured at telecommunications wavelengths. The serially coupled rings are modeled using a simple transfer matrix approach. G...

متن کامل

Ring-coupled Mach-Zehnder interferometer optimized for sensing.

We demonstrate numerically that the theoretical maximum sensitivity of a ring-coupled Mach-Zehnder interferometer (MZI) optimized as a sensor is about 30% greater than the optimized sensitivity of a conventional single-bus ring sensor with an identical ring perimeter and loss. The ring-coupled MZI sensor also achieves its greater sensitivity with a 25% lower circulating power, which is useful f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 30 13  شماره 

صفحات  -

تاریخ انتشار 2005